EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?

Glen P Kenny iD, Kelli E McCormick, Fergus K O'Connor iD, James J McCormick

Experimental Physiology · 2026-11-14

DOI: 10.1113/ep094380 ↗

At a glance

Journal article in Experimental Physiology, published online on 2026-11-14. Written by Glen P Kenny and 3 co-authors. Institution: Human and Environmental Physiology Research Unit, School of Human Kinetics, University of Ottawa, Ottawa, Ontario, Canada. 21 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Ceiling fans are a low‐energy strategy for reducing heat strain, but their ability to protect against subclinical cellular and organ stress is unknown. We examined circulating stress biomarkers in 20 older adults (12 females; median age 71 years), who completed randomized 8 h exposures to 31°C and 45% relative humidity while remaining reclined beneath a ceiling fan delivering 0 m s −1 (control) or 1.5 m s −1 (fan). Venous blood was collected before and after each exposure and analysed for serum intestinal fatty acid‐binding protein (IFABP), soluble cluster of differentiation 14 (sCD14), kidney injury molecule‐1, neutrophil gelatinase‐associated lipocalin, tumour necrosis factor‐α, interleukin‐6 and C‐reactive protein. Core temperature and heart rate were measured continuously. Biomarker responses were assessed using baseline‐adjusted linear mixed‐effects models with Holm correction for multiple testing. Fan use lowered peak core temperature and heart rate by 0.2°C ( P < 0.001) and 5 beats min −1 ( P = 0.030), respectively. The adjusted difference in IFABP change between control and fan was 344 pg mL −1 [95% confidence interval: 102–586] (unadjusted P = 0.005; Holm‐adjusted P = 0.035). Across conditions, the estimated changes in IFABP and sCD14 were 240 pg mL −1 [95% confidence interval: 11–468] (Holm‐adjusted P = 0.240) and 0.57 ng mL −1 [95% confidence interval: 0.10–1.03] (Holm‐adjusted P = 0.119), respectively. No other biomarker comparisons remained significant after Holm adjustment. Ceiling‐fan use at 31°C attenuated the IFABP response in bed‐resting older adults despite modest effects on core temperature and heart rate. These exploratory findings suggest that fan‐mediated protection might extend beyond changes captured by conventional physiological measures, but confirmation in prospectively powered studies incorporating direct measures of gastrointestinal permeability is required.

Subjects

Author keywords

ageinggastrointestinal barrierheat stressindoor overheatinginflammationrenal injury

Authors and institutions

  • Human and Environmental Physiology Research Unit, School of Human Kinetics, University of Ottawa, Ottawa, Ontario, Canada.
  • Institute of the Environment, University of Ottawa, Ottawa, Canada.
  • Interdisciplinary School of Health Sciences, Faculty of Health Sciences, University of Ottawa, Ottawa, Ontario, Canada.
  • Clinical Epidemiological Program, Ottawa Hospital Research Institute, Ottawa, Ontario, Canada.
  • School of Allied Health, Sport and Social Work, Griffith University, Southport, Queensland, Australia.
  • Allied Health Research Collaborative, The Prince Charles Hospital, Chermside, Queensland, Australia.

ORCID profiles: Glen P Kenny, Fergus K O'Connor

Cite

APA

Kenny, G. P., McCormick, K. E., O'Connor, F. K., & McCormick, J. J. (2026). Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?. Experimental Physiology. https://doi.org/10.1113/ep094380

Vancouver

Kenny GP, McCormick KE, O'Connor FK, McCormick JJ. Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?. Experimental Physiology. 2026. doi:10.1113/ep094380

BibTeX
@article{Kenny2026,
  author = {Kenny, Glen P and McCormick, Kelli E and O'Connor, Fergus K and McCormick, James J},
  title = {Does ceiling‐fan use modify circulating markers of heat‐related stress in bed‐resting older adults?},
  journal = {Experimental Physiology},
  year = {2026},
  doi = {10.1113/ep094380}
}
Start for free →