Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea
Experimental Physiology · 21.11.2026
DOI: 10.1113/ep094174 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, online erschienen am 21.11.2026. Verfasst von Jack R. Dunsford und 3 weiteren Autor:innen. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Research Manitoba.
Abstract (Originalsprache)
The diaphragm electromyogram (EMG DIA ) is commonly used as a proxy for inspiratory neural drive (IND) based on correlative evidence; however, robust experimental evidence supporting its use is lacking. To determine the effects of independent changes in minute ventilation () and the partial pressure of end‐tidal carbon dioxide () on EMG DIA . n = 10 healthy adults (20–40 years; n = 5 males, n = 5 females) completed spirometry, a 10‐min rest period and a series of hyperpnoea trials at three standardized levels of by having participants breathe according to tidal volume ( V T ) and breathing frequency ( F B ) targets. Within each level of , was set to −5, +0 or +5 mmHg relative to resting using dynamic end‐tidal forcing. Trials were performed in a quasi‐randomized, single‐blind manner. EMG DIA was assessed using an intraoesophageal catheter, standard ventilatory and gas exchange variables were collected, and the perception of dyspnoea intensity was assessed using the Borg category‐ratio 0–10 scale. EMG DIA increased significantly with ( P < 0.001) but was unaffected by changes in ( P = 0.320). Moreover, EMG DIA was significantly associated with , the work of breathing, and the pressure–time product of the diaphragm ( R 2 = 0.762–0.824; all P < 0.001), but not ( R 2 = 0.529; P = 0.947). Dyspnoea perception increased significantly with ( P < 0.001) and ( P < 0.001). During voluntary hyperpnoea involving manipulations of across a physiological range observed with exercise (i.e., 5 mmHg below and above resting ), EMG DIA reflects the mechanical ventilatory output of IND rather than changes in the drive to breathe due to variations in .
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Research Manitoba
Zitieren
APA
Dunsford, J. R., Mann, L. M., Dominelli, P. B., & Molgat‐Seon, Y. (2026). Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea. Experimental Physiology. https://doi.org/10.1113/ep094174
Vancouver
Dunsford JR, Mann LM, Dominelli PB, Molgat‐Seon Y. Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea. Experimental Physiology. 2026. doi:10.1113/ep094174
BibTeX
@article{Dunsford2026,
author = {Dunsford, Jack R. and Mann, Leah M. and Dominelli, Paolo B. and Molgat‐Seon, Yannick},
title = {Evaluating the effects of changes in minute ventilation and the partial pressure of end‐tidal carbon dioxide on the diaphragm electromyogram during voluntary hyperpnoea},
journal = {Experimental Physiology},
year = {2026},
doi = {10.1113/ep094174}
}
EUVIMED