EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner

Lucas Ugliara iD, Lucas B R Orssatto iD, Amilton Vieira iD, Gabriel S Trajano iD

Experimental Physiology · 2026

DOI: 10.1113/ep092961 ↗

At a glance

Journal article in Experimental Physiology, 2026. Written by Lucas Ugliara and 3 co-authors. Institution: Faculty of Physical Education, University of Brasilia (UnB), Brasilia, Brazil. Major MEDLINE topics: Motor Neurons, Hand Strength, Isometric Contraction, Muscle, Skeletal. Cited 1 times so far (Crossref); 54 references. The full text is freely available (open access, CC BY 4.0). Funded by: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

The contribution of persistent inward currents (PICs) to motoneuron firing in the lower limb typically increases after a remote handgrip contraction, believed to result from diffuse serotonergic input increases in spinal cord. We investigated whether handgrip contraction intensity, duration and/or impulse would affect PIC estimates in tibialis anterior motoneurons. Multi‐channel electromyograms were recorded from the tibialis anterior of 21 participants (18–40 years), during dorsiflexions at 20% of the individuals’ maximal torque, before and after four handgrip conditions: (i) 80% of their maximal handgrip strength sustained for 15 s (80%15s); (ii) 40% sustained for 15 s (40%15s); (iii) 40% sustained for 30 s (40%30s); and (iv) no handgrip (Control). The PIC contribution to self‐sustained motoneuron firing was estimated with delta frequency (Δ F ) using paired motor unit analysis. The ‘brace height’, normalised as a percentage of a right triangle (% rTri), was used to estimate the PIC effects on the non‐linearity of firing patterns, representing the neuromodulatory drive (metabotropic regulation of motoneuron excitability) onto the motoneurons. Δ F increased by 0.33 pulses per second (pps; 95% CI: 0.16–0.49, d = 0.47) after 40%30s and by 0.24 pps (0.09–0.38, d = 0.34) after 80%15s, but remained unchanged after 40%15s and Control. Similarly, brace height increased by 2.24% rTri (0.18–4.30, d = 0.20) after 40%30s and by 2.45% rTri (0.64–4.25, d = 0.22) after 80%15s, remaining unchanged after 40%15s and Control. The increase in the PIC contribution to motoneuron firing induced by a remote handgrip contraction is impulse dependent rather than intensity or duration dependent. The parallel increases in Δ F and brace height suggest augmented neuromodulatory input onto the spinal cord.

Subjects

MeSH terms (MEDLINE)

Motor NeuronsHand StrengthIsometric ContractionMuscle, SkeletalHumansElectromyographyMaleYoung AdultFemaleAdultAdolescentAction Potentials

Author keywords

EMGPICmotoneuronneuromodulationremote contractionserotonin

Authors and institutions

  • Faculty of Physical Education, University of Brasilia (UnB), Brasilia, Brazil.
  • Centre for Sensorimotor Performance, School of Human Movement and Nutrition Sciences, The University of Queensland, Brisbane, Queensland, Australia.
  • Faculty of Health, School of Exercise and Nutrition Sciences, Queensland University of Technology (QUT), Brisbane, Queensland, Australia.

ORCID profiles: Lucas Ugliara, Lucas B R Orssatto, Amilton Vieira, Gabriel S Trajano

Funding

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Cite

APA

Ugliara, L., Orssatto, L. B. R., Vieira, A., & Trajano, G. S. (2026). Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner. Experimental Physiology. https://doi.org/10.1113/ep092961

Vancouver

Ugliara L, Orssatto LBR, Vieira A, Trajano GS. Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner. Experimental Physiology. 2026. doi:10.1113/ep092961

BibTeX
@article{Ugliara2026,
  author = {Ugliara, Lucas and Orssatto, Lucas B R and Vieira, Amilton and Trajano, Gabriel S},
  title = {Isometric handgrip contraction increases tibialis anterior intrinsic motoneuron excitability in a dose‐dependent manner},
  journal = {Experimental Physiology},
  year = {2026},
  doi = {10.1113/ep092961}
}
Start for free →