EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Limited matching of the cardiac output response to the peripheral demand of heat stress and exercise

Moritz Lampkemeyer iD, Jonas Kell iD, Veit Börß, Tobias Claussen, Fabian Spahiu iD, Michelle Ottlik iD, Lars C Helbig iD, Craig G Crandall iD, Eric J Stöhr iD

Experimental Physiology · 2025-05 · 110 (5) · 722-734

DOI: 10.1113/ep092688 ↗

At a glance

Journal article in Experimental Physiology, published online on 2025-03-20. Written by Moritz Lampkemeyer and 8 co-authors. Institution: COR-HELIX, Institute of Sport Science, Leibniz University, Hannover, Germany. Major MEDLINE topics: Cardiac Output, Exercise, Heat-Shock Response, Heat Stress Disorders. Cited 7 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIA NIH HHS, Leibniz University Hannover.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

It is widely accepted that cardiac output matches the prevailing peripheral demand in healthy humans. However, it remains unknown whether stroke volume and heart rate are regulated interdependently to arrive at a specific cardiac output. The aim of this study was to determine whether the healthy human heart responds specifically according to the peripheral demands of heat stress and exercise. Eleven healthy humans (women/men n = 3/8; age = 26 ± 2 years; body mass = 73 ± 11 kg) underwent leg heat stress and cycling exercise (60 W), with and without blood flow restriction (pressure set at the prevailing mean arterial pressure of the individual). Cardiac output was measured with triplane echocardiography. Additionally, haemodynamics, oxygen consumption, carbon dioxide production and lactate were assessed. Data were analysed using two‐way repeated‐measures ANOVA. Despite stable heat and exercise demands, cardiac output decreased significantly with blood flow restriction in both conditions (Δ−0.87 and −1.03 L min −1 , 17% and 11%, respectively, p = 0.01), owing to a decline in end‐diastolic volume ( p < 0.0001) and stroke volume ( p < 0.0001) not sufficiently compensated for by an increase in heart rate ( p = 0.001). Importantly, these responses were accompanied by an increased rate of skin temperature rise ( p = 0.04) during heat stress and a significantly greater rise in circulating lactate ( p < 0.0001) during exercise. The cardiac output response to local heat stress and submaximal exercise does not appear to be entirely specific to the peripheral thermal and energetic requirements. This finding supports the theory that even the healthy heart does not coordinate stroke volume and heart rate to arrive at a specific target output.

Subjects

MeSH terms (MEDLINE)

Cardiac OutputExerciseHeat-Shock ResponseHeat Stress DisordersHumansFemaleAdultMaleHeart RateStroke VolumeOxygen ConsumptionLactic AcidRegional Blood FlowYoung AdultHemodynamicsSkin TemperatureBlood PressureHot TemperatureCarbon Dioxide

Author keywords

blood flowblood flow restrictioncardiovascular controlcardiovascular responseexerciseexercise physiologyheat stress

Substances

Lactic AcidCarbon Dioxide

Authors and institutions

  • COR-HELIX, Institute of Sport Science, Leibniz University, Hannover, Germany.
  • Division of Cardiology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Institute for Exercise and Environmental Medicine, Dallas, Texas, USA.
  • Division of Cardiology, Columbia University Irving Medical Center, New York, New York, USA.

ORCID profiles: Moritz Lampkemeyer, Jonas Kell, Fabian Spahiu, Michelle Ottlik, Lars C Helbig, Craig G Crandall, Eric J Stöhr

Funding

  • NIA NIH HHS
  • Leibniz University Hannover

Cite

APA

Lampkemeyer, M., Kell, J., Börß, V., Claussen, T., Spahiu, F., Ottlik, M., Helbig, L. C., Crandall, C. G., & Stöhr, E. J. (2025). Limited matching of the cardiac output response to the peripheral demand of heat stress and exercise. Experimental Physiology, 110(5), 722-734. https://doi.org/10.1113/ep092688

Vancouver

Lampkemeyer M, Kell J, Börß V, Claussen T, Spahiu F, Ottlik M, et al. Limited matching of the cardiac output response to the peripheral demand of heat stress and exercise. Experimental Physiology. 2025;110(5):722-734. doi:10.1113/ep092688

BibTeX
@article{Lampkemeyer2025,
  author = {Lampkemeyer, Moritz and Kell, Jonas and Börß, Veit and Claussen, Tobias and Spahiu, Fabian and Ottlik, Michelle and Helbig, Lars C and Crandall, Craig G and Stöhr, Eric J},
  title = {Limited matching of the cardiac output response to the peripheral demand of heat stress and exercise},
  journal = {Experimental Physiology},
  year = {2025},
  volume = {110},
  number = {5},
  pages = {722--734},
  doi = {10.1113/ep092688}
}
Start for free →