EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Nocturnal pulse oxygen saturation dynamics at simulated high altitude: Predictive value for acute mountain sickness in healthy men born pre‐term

Benjamin J Narang iD, Giorgio Manferdelli, Grégoire P Millet iD, Tadej Debevec iD

Experimental Physiology · 2025

DOI: 10.1113/ep092418 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experimental Physiology, 2025. Verfasst von Benjamin J Narang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department for Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Altitude Sickness, Altitude, Oxygen Saturation, Oxygen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian National Research Agency, Swiss National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The physiological sequelae of pre‐term birth might influence the responses of this population to hypoxia. Moreover, identifying variables associated with development of acute mountain sickness (AMS) remains a key practically significant area of altitude research. We investigated the effects of pre‐term birth on nocturnal oxygen saturation () dynamics and assessed the predictive potential of nocturnal ‐related metrics for morning AMS in 12 healthy adults with gestational age < 32 weeks (pre‐term) and 12 term‐born control participants. Participants spent one night at a simulated altitude of ∼4200 m (normobaric hypoxia; fraction of inspired O 2 = 0.141), with nocturnal and heart rate recorded continuously at the fingertip using pulse oximetry and with morning AMS assessed using the Lake Louise scale. Pre‐term and term‐born participants had similar nocturnal mean (mean ± SD; 77% ± 3% vs. 77% ± 4%; P = 0.661), minimum (median[IQR]; 67[4]% vs. 69[5]%; P = 0.223), relative time spent with < 80% (72% ± 29% vs. 70% ± 27%; P = 0.879) and mean heart rate (79 ± 12 vs. 71 ± 7 beats/min; P = 0.053). However, the increase in between the two halves of the night was blunted with prematurity (−0.12% ± 1.51% vs. 1.11% ± 0.78%; P = 0.021). Moreover, the cumulative relative desaturation‐based hypoxic ‘load’ was higher with prematurity (32[26]%min/h vs. 7[25]%min/h; P = 0.039), underpinned by increased desaturation frequency (69[49] vs. 21[35] counts/h; P = 0.009). Mean , minimum , morning and relative time spent with < 80% predicted AMS incidence better than a random classifier exclusively in the pre‐term group, with no other variables predictive of AMS in the two groups separately or combined. Overall, pre‐term birth might alter nocturnal dynamics and influence AMS prediction in severe hypoxia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Altitude SicknessAltitudeOxygen SaturationOxygenCircadian RhythmHumansMaleAdultHypoxiaYoung AdultHeart RateOximetry

Stichwörter der Autor:innen

hypoxiaprematuritypulse oximetrysleep

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department for Automatics, Biocybernetics and Robotics, Jožef Stefan Institute, Ljubljana, Slovenia.
  • Faculty of Sport, University of Ljubljana, Ljubljana, Slovenia.
  • Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Dallas, Dallas, Texas, USA.
  • Institute for Sport Sciences, University of Lausanne, Lausanne, Switzerland.

ORCID-Profile: Benjamin J Narang, Grégoire P Millet, Tadej Debevec

Förderung

  • Slovenian National Research Agency
  • Swiss National Science Foundation

Zitieren

APA

Narang, B. J., Manferdelli, G., Millet, G. P., & Debevec, T. (2025). Nocturnal pulse oxygen saturation dynamics at simulated high altitude: Predictive value for acute mountain sickness in healthy men born pre‐term. Experimental Physiology. https://doi.org/10.1113/ep092418

Vancouver

Narang BJ, Manferdelli G, Millet GP, Debevec T. Nocturnal pulse oxygen saturation dynamics at simulated high altitude: Predictive value for acute mountain sickness in healthy men born pre‐term. Experimental Physiology. 2025. doi:10.1113/ep092418

BibTeX
@article{Narang2025,
  author = {Narang, Benjamin J and Manferdelli, Giorgio and Millet, Grégoire P and Debevec, Tadej},
  title = {Nocturnal pulse oxygen saturation dynamics at simulated high altitude: Predictive value for acute mountain sickness in healthy men born pre‐term},
  journal = {Experimental Physiology},
  year = {2025},
  doi = {10.1113/ep092418}
}
Kostenlos starten →