EUVIMEDDescobrir EUVIMED
Randomisierte kontrollierte StudieOpen access · CC BY 4.0

Pulmonary diffusing capacity to nitric oxide and carbon monoxide during exercise and in the supine position: a test–retest reliability study

Anna Christrup Madsen iD, Rie Skovly Thomsen iD, Stine B Nymand iD, Jacob Peter Hartmann iD, Iben E Rasmussen iD, Milan Mohammad iD, Lene Theil Skovgaard iD, Birgitte Hanel, Simon Jønck iD, Ulrik Winning Iepsen iD, Regitse H Chistensen iD, Jann Mortensen iD and 1 more

Experimental Physiology · 2023

DOI: 10.1113/ep090883 ↗

At a glance

Randomisierte kontrollierte Studie in Experimental Physiology, 2023. Written by Anna Christrup Madsen and 12 co-authors. Institution: Centre for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark. Major MEDLINE topics: Pulmonary Diffusing Capacity, Carbon Monoxide. Cited 16 times so far (Crossref); 39 references. The full text is freely available (open access, CC BY 4.0).

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

D LCO/NO , the combined single‐breath measurement of the diffusing capacity to carbon monoxide ( D LCO ) and nitric oxide ( D LNO ) measured either during exercise or in the resting supine position may be a useful physiological measure of alveolar–capillary reserve. In the present study, we investigated the between‐day test–retest reliability of D LCO/NO ‐based metrics. Twenty healthy volunteers (10 males, 10 females; mean age 25 (SD 2) years) were randomized to repeated D LCO/NO measurements during upright rest followed by either exercise ( n = 11) or resting in the supine position ( n = 9). The measurements were repeated within 7 days. The smallest real difference (SRD), defined as the 95% confidence limit of the standard error of measurement (SEM), the coefficient of variance (CV), and intraclass correlation coefficients were used to assess test–retest reliability. SRD for D LNO was higher during upright rest (5.4 (95% CI: 4.1, 7.5) mmol/(min kPa)) than during exercise (2.7 (95% CI: 2.0, 3.9) mmol/(min kPa)) and in the supine position (3.0 (95% CI: 2.1, 4.8) mmol/(min kPa)). SRD for D LCOc was similar between conditions. CV values for D LNO were slightly lower than for D LCOc both during exercise (1.5 (95% CI: 1.2, 1.7) vs. 3.8 (95% CI: 3.2, 4.3)%) and in the supine position (2.2 (95% CI: 1.8, 2.5) vs. 4.8 (95% CI: 3.8, 5.4)%). D LNO increased by 12.3 (95% CI: 11.1, 13.4) and D LCOc by 3.3 (95% CI: 2.9, 3.7) mmol/(min kPa) from upright rest to exercise. The D LCO/NO technique provides reliable indices of alveolar–capillary reserve, both during exercise and in the supine position.

Subjects

MeSH terms (MEDLINE)

Pulmonary Diffusing CapacityCarbon MonoxideMaleFemaleHumansAdultNitric OxideReproducibility of ResultsSupine Position

Author keywords

alveolar-capillary reservepulmonary gas exchangerepeatability

Substances

Carbon MonoxideNitric Oxide

Authors and institutions

  • Centre for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
  • Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
  • Department of Biostatistics, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
  • Department of Anaesthesiology and Intensive Care, Copenhagen University Hospital - Bispebjerg Hospital, Copenhagen, Denmark.
  • Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

ORCID profiles: Anna Christrup Madsen, Rie Skovly Thomsen, Stine B Nymand, Jacob Peter Hartmann, Iben E Rasmussen, Milan Mohammad, Lene Theil Skovgaard, Simon Jønck, Ulrik Winning Iepsen, Regitse H Chistensen, Jann Mortensen, Ronan M G Berg

Cite

APA

Madsen, A. C., Thomsen, R. S., Nymand, S. B., Hartmann, J. P., Rasmussen, I. E., Mohammad, M., Skovgaard, L. T., Hanel, B., Jønck, S., Iepsen, U. W., Chistensen, R. H., Mortensen, J., & Berg, R. M. G. (2023). Pulmonary diffusing capacity to nitric oxide and carbon monoxide during exercise and in the supine position: a test–retest reliability study. Experimental Physiology. https://doi.org/10.1113/ep090883

Vancouver

Madsen AC, Thomsen RS, Nymand SB, Hartmann JP, Rasmussen IE, Mohammad M, et al. Pulmonary diffusing capacity to nitric oxide and carbon monoxide during exercise and in the supine position: a test–retest reliability study. Experimental Physiology. 2023. doi:10.1113/ep090883

BibTeX
@article{Madsen2023,
  author = {Madsen, Anna Christrup and Thomsen, Rie Skovly and Nymand, Stine B and Hartmann, Jacob Peter and Rasmussen, Iben E and Mohammad, Milan and Skovgaard, Lene Theil and Hanel, Birgitte and Jønck, Simon and Iepsen, Ulrik Winning and Chistensen, Regitse H and Mortensen, Jann and Berg, Ronan M G},
  title = {Pulmonary diffusing capacity to nitric oxide and carbon monoxide during exercise and in the supine position: a test–retest reliability study},
  journal = {Experimental Physiology},
  year = {2023},
  doi = {10.1113/ep090883}
}
Start for free →