Comparison of canine femoral implant templating for total hip arthroplasty on 25 sets of craniocaudal extended and caudocranial flexed hip radiographs

Nathan Zab, Daniel A Degner, Charles E DeCamp, Cody Doyle, Sarah Lloyd

Veterinary Surgery · 2025

DOI: 10.1111/vsu.70065 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Nathan Zab und 4 weiteren Autor:innen. Beteiligte Einrichtung: Animal Surgical Center of Michigan, Flint, Michigan, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Radiography, Femur. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine whether radiographic templating of femoral stem size for total hip arthroplasty (THA) using extended and flexed hip radiographs are interchangeable. Study design Retrospective radiographic study. Sample population A total of 25 dogs evaluated as THA candidates.

Methods

Hip‐extended and hip‐flexed radiographs were templated for femoral stem implant size by three surgeons. A fourth investigator measured femoral length, canal flare index (CFI), and osteoarthritis scores for each projection and recorded implant size from surgical records. Templated stem sizes from each projection were compared with the implanted stem sizes using Bland–Altman analysis. Descriptive statistics were reported based on data distribution.

Results

Templated femoral stem size differed between surgeons ( p = .014); the median (IQR) stem size was #9 (8–10) for one surgeon, compared to #8 (7–9) for the other surgeons. Templated stem sizes on extended and flexed radiographs were #8 (7–9) and #9 (7–9), respectively ( p < .0001). The mean (SD) CFI in extended and flexed projections were 1.61 (0.21) and 1.89 (0.30), respectively ( p < .0001). Implant size was underestimated using the extended projection (mean difference: −0.54) and overestimated using the flexed projection (mean difference: 0.30). Positive proportional bias was present between the extended and flexed projections (slopes: 0.22 and 0.25; p < .003).

Conclusion

Neither templating method consistently predicted the clinical femoral stem implant size. Clinical significance Hip‐flexed templating may serve as a practical alternative when extended projections are not possible, though intraoperative assessment remains essential for final implant selection, particularly since measurement bias increased for stems larger than size 9.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisRadiographyFemurDog DiseasesDogsAnimalsRetrospective StudiesFemaleMaleHip Joint

Autor:innen und Institutionen

  • Animal Surgical Center of Michigan, Flint, Michigan, USA.
  • MedVet Mandeville, Mandeville, Louisiana, USA.

Zitieren

APA

Zab, N., Degner, D. A., DeCamp, C. E., Doyle, C., & Lloyd, S. (2025). Comparison of canine femoral implant templating for total hip arthroplasty on 25 sets of craniocaudal extended and caudocranial flexed hip radiographs. Veterinary Surgery. https://doi.org/10.1111/vsu.70065

Vancouver

Zab N, Degner DA, DeCamp CE, Doyle C, Lloyd S. Comparison of canine femoral implant templating for total hip arthroplasty on 25 sets of craniocaudal extended and caudocranial flexed hip radiographs. Veterinary Surgery. 2025. doi:10.1111/vsu.70065

BibTeX
@article{Zab2025,
  author = {Zab, Nathan and Degner, Daniel A and DeCamp, Charles E and Doyle, Cody and Lloyd, Sarah},
  title = {Comparison of canine femoral implant templating for total hip arthroplasty on 25 sets of craniocaudal extended and caudocranial flexed hip radiographs},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.70065}
}
Kostenlos starten →