Kurz gefasst

Vergleichsstudie in der Zeitschrift HIP International, online erschienen am 15.05.2026. Verfasst von Adrien D'Ambrosio und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Strasbourg University Hospitals, Strasbourg, France. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Prosthesis Design, Femur. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

In Dorr type A femurs (DTAF), the flared anatomy renders proximal femoral filling (PFF) with a standard-length stem (STA) challenging, although this is essential to ensure favourable outcomes. This study compared clinical and radiographic outcomes between standard and shortened versions of a same cementless stem in DTAF. Our hypothesis was that there would be no differences in clinical outcomes, PFF or osseointegration between the 2 stems.

Methods

We reviewed 87 THA files performed in DTAF from 2013 to 2015 for STA and from 2015 to 2019 for shortened-length stems (SHO). At minimum 2-year follow-up, 8 patients were unavailable for evaluation, leaving 79 THA: 34 STA and 45 SHO. Femoral morphology was assessed preoperatively with the canal-calcar ratio (CCR) and canal bone ratio (CBR). Outcomes included: Oxford Hip Score (OHS) and PMA, proximal canal fill ratio (CFR)(A) and (B), stem subsidence and alignment, distal cortical hypertrophy, and Engh score.

Results

There were no significant differences in clinical outcomes, PFF and osseointegration between the 2 groups. Greater migration was observed in STA. Distal cortical hypertrophy was seen exclusively in SHO and was significantly associated with a worse OHS. CCR was significantly correlated with proximal CFR. Aligned stems were significantly associated with higher CFR(B).

Conclusions

There were no differences in clinical or radiographic outcomes of STA and SHO in DTAF. Increasing CFR enhanced stem alignment, while femoral morphology significantly influenced PFF. SHO migrated less, but exhibited distal cortical hypertrophy, which may indicate early stress-shielding and challenge the stem’s “short” designation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisProsthesis DesignFemurHumansFemaleRetrospective StudiesMaleMiddle AgedRadiographyTreatment OutcomeOsseointegrationAged

Stichwörter der Autor:innen

Canal fillingfemoral morphologyosseointegrationshort stemtotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Strasbourg University Hospitals, Strasbourg, France.
  • Department of Public Health, Strasbourg University Hospitals, Strasbourg, France.
  • Department of Orthopaedic Surgery, Surgical Center Emile Gallé, Nancy, France.

ORCID-Profile: Adrien D'Ambrosio

Zitieren

APA

D'Ambrosio, A., Goetsch, T., Roche, O., & Bonnomet, F. (2026). No differences in clinical and radiographic outcomes between standard and shortened versions of a same cementless femoral stem in Dorr type A femurs. HIP International, 36(6), 914-921. https://doi.org/10.1177/11207000261441838

Vancouver

D'Ambrosio A, Goetsch T, Roche O, Bonnomet F. No differences in clinical and radiographic outcomes between standard and shortened versions of a same cementless femoral stem in Dorr type A femurs. HIP International. 2026;36(6):914-921. doi:10.1177/11207000261441838

BibTeX
@article{DAmbrosio2026,
  author = {D'Ambrosio, Adrien and Goetsch, Thibaut and Roche, Olivier and Bonnomet, François},
  title = {No differences in clinical and radiographic outcomes between standard and shortened versions of a same cementless femoral stem in Dorr type A femurs},
  journal = {HIP International},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {914--921},
  doi = {10.1177/11207000261441838}
}