Diagnostic accuracy of ultrasonographic evaluation prior to laparoscopic‐assisted gastrointestinal foreign body removal in 30 dogs
Veterinary Surgery · 2026
DOI: 10.1111/vsu.70045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Darby D Toth und 4 weiteren Autor:innen. Beteiligte Einrichtung: Kansas State University College of Veterinary Medicine, Manhattan, Kansas, USA. Hauptthemen laut MEDLINE: Laparoscopy, Foreign Bodies, Dog Diseases. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Karen Hale Young Grant, Mark Derrick Grant, Kansas State University.
Abstract (Originalsprache)
Objective
To determine the ability of abdominal ultrasound (AUS) to correctly identify gastrointestinal foreign body (GIFB) type, location, size and shape; and to determine the success rate of laparoscopic‐assisted GIFB removal with GIFB of various characteristics. Study design Prospective clinical study. Animals Client‐owned dogs (30) that underwent laparoscopic‐assisted intestinal surgery (LAIS).
Methods
Dogs with GIFB obstruction underwent an AUS performed by a boarded radiologist. GIFB type, location within the gastrointestinal tract, size, and shape were recorded, as well as the presence or absence of peritoneal fluid, pneumoperitoneum, or mural changes. LAIS was attempted in all dogs. Surgical findings were compared to ultrasound findings.
Results
AUS was able to correctly determine the type, location, and shape of GIFB 96.8%, 77.42%, and 93.5% of the time, respectively. AUS had moderate accuracy (80%), at identifying adhesions, and underestimated GIFB size. LAIS was successful in 16/30 (53.3%) of cases, including 2/7 (28.6%) linear, 14/23 (60.9%) non‐linear, and 1/1 (100%) gastric foreign bodies, but was not successful for GIFB near the caudal duodenal flexure (0/2, 0%).
Conclusion
Preoperative AUS was accurate in determining the type, location, and shape of GIFB. Specific linear foreign bodies were amenable to laparoscopic‐assisted removal. GIFB located at the caudal duodenal flexure were not successfully removed by LAIS. Clinical significance Preoperative AUS is a useful diagnostic to aid in determining the suitability of a dog to undergo LAIS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Kansas State University College of Veterinary Medicine, Manhattan, Kansas, USA.
- Department of Statistics, Kansas State University, Manhattan, Kansas, USA.
ORCID-Profile: Darby D Toth
Förderung
- Karen Hale Young Grant
- Mark Derrick Grant
- Kansas State University
Zitieren
APA
Toth, D. D., Upchurch, D. A., Kerns, A. W., Hallman, R. M., & Cassel, N. (2026). Diagnostic accuracy of ultrasonographic evaluation prior to laparoscopic‐assisted gastrointestinal foreign body removal in 30 dogs. Veterinary Surgery. https://doi.org/10.1111/vsu.70045
Vancouver
Toth DD, Upchurch DA, Kerns AW, Hallman RM, Cassel N. Diagnostic accuracy of ultrasonographic evaluation prior to laparoscopic‐assisted gastrointestinal foreign body removal in 30 dogs. Veterinary Surgery. 2026. doi:10.1111/vsu.70045
BibTeX
@article{Toth2026,
author = {Toth, Darby D and Upchurch, David A and Kerns, Aidan W and Hallman, R Mackenzie and Cassel, Nicolette},
title = {Diagnostic accuracy of ultrasonographic evaluation prior to laparoscopic‐assisted gastrointestinal foreign body removal in 30 dogs},
journal = {Veterinary Surgery},
year = {2026},
doi = {10.1111/vsu.70045}
}
EUVIMED