EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Comparing 3 mm and 5 mm laparoscopic liver biopsy samples in dogs

Philippe Chagnon Larose, Brigitte A Brisson, Robert A Foster, Gabrielle Monteith

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14006 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Philippe Chagnon Larose und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada. Hauptthemen laut MEDLINE: Laparoscopy, Liver, Dog Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: OVC Pet Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine whether 3 mm cup biopsy forceps (CBF) provide equivalent diagnostic samples to 5 mm CBF for histopathologic diagnosis, bacterial culture, and copper quantification. Study design Clinical prospective study. Animals Ten client‐owned dogs, presenting for laparoscopic liver biopsy (LLB).

Methods

Dogs underwent LLB, and paired samples were collected using 3 and 5 mm CBF. Portal triad and hepatic lobule counts, crush and fragmentation artifacts, copper concentration, bacterial culture results, and agreement on histopathologic diagnosis were compared.

Results

Both CBF sizes allowed for easy sample collection and resulted in minimal hemorrhage. An average of 12.13 (confidence limit (CL): 9.4–14.9) and 17.84 (CL: 15.1–20.6) portal triads were obtained using a 3 and 5 mm CBF, respectively ( p = .0003). A portal triad count of 11 or more was achieved in 73.3% of the 3 mm and 93.3% of the 5 mm samples. Gwets AC1 coefficient showed a high level of agreement (0.8) for overall histopathologic diagnosis ( p < .0001). The 3 mm CBF crush scores were higher (median of the differences: −1; range: −1 to 1) ( p = .035). There was no difference in fragmentation scores ( p = .935).

Conclusion

The 3 mm CBF yielded smaller samples in terms of size and portal triad count compared with the 5 mm CBF. However, the portal triad count was sufficient in a majority of samples and histologic agreement with the 5 mm CBF was excellent. Clinical significance In dogs, a 3 mm CBF yields adequate samples for histopathologic interpretation, copper quantification, and bacterial culture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopyLiverDog DiseasesAnimalsDogsBiopsyProspective StudiesMaleFemaleLiver Diseases

Autor:innen und Institutionen

  • Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
  • Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.

Förderung

  • OVC Pet Trust

Zitieren

APA

Larose, P. C., Brisson, B. A., Foster, R. A., & Monteith, G. (2024). Comparing 3 mm and 5 mm laparoscopic liver biopsy samples in dogs. Veterinary Surgery. https://doi.org/10.1111/vsu.14006

Vancouver

Larose PC, Brisson BA, Foster RA, Monteith G. Comparing 3 mm and 5 mm laparoscopic liver biopsy samples in dogs. Veterinary Surgery. 2024. doi:10.1111/vsu.14006

BibTeX
@article{Larose2024,
  author = {Larose, Philippe Chagnon and Brisson, Brigitte A and Foster, Robert A and Monteith, Gabrielle},
  title = {Comparing 3 mm and 5 mm laparoscopic liver biopsy samples in dogs},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14006}
}
Kostenlos starten →