Biomechanical testing of three constructs for prosthetic laryngoplasty in horses demonstrates advantages of differing metallic implants in the arytenoid cartilage
Veterinary Surgery · 2026
DOI: 10.1111/vsu.14328 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Machiel P Ysebaert und 7 weiteren Autor:innen. Beteiligte Einrichtung: Colorado State University, Veterinary Teaching Hospital, Fort Collins, Colorado, USA. Hauptthemen laut MEDLINE: Arytenoid Cartilage, Laryngoplasty, Prostheses and Implants. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Colorado State University College Research Council Colorado Racing Commission.
Abstract (Originalsprache)
Objective
To compare the biomechanical stability of a novel arytenoid implant (tie‐bolt, TB) with a suture anchor (SA) and standard laryngoplasty using suture alone (control) in equine larynges. Study design Randomized ex vivo controlled experimental study. Sample population Thirty equine cadaver larynges.
Methods
Larynges were randomly assigned to TB, SA, or control groups (n = 10 each). The force of abduction was measured for each construct, then constructs underwent cyclic loading (5–50 N for 3000 cycles) to assess elongation, followed by load‐to‐failure testing to assess ultimate load, displacement, stiffness, and mode of failure.
Results
The SA required less force to achieve 88% abduction (8.31 ± 2.46 N) than the TB (11.48 ± 3.6 N, p = .07) and controls (11.86 ± 2.99 N, p = .04). The TB had less construct elongation (2.62 ± 0.61 mm) than SA constructs (3.87 ± 1.25 mm, p = .01) and was stiffer (31.05 ± 3.38 N/mm) than both control (23.48 ± 2.06 N/mm, p < .0001) and SA constructs (18.53 ± 4.15 N/mm, p < .0001). The TB construct failed at higher ultimate load and displacement (367.25 ± 66.98 N and 19.11 ± 2.51 mm, respectively) than the control (238.14 ± 19.46 N and 14.23 ± 1.6 mm; p < .0001 for both) and SA constructs (196.55 ± 47.17 N and 16.23 ± 2.02 mm; p < .0001 and p = .01, respectively). The primary modes of failure were suture cut‐through for control, implant pullout for SA, and arytenoid fracture for TB.
Conclusion
The SA required the least force for abduction. The TB was a stiffer construct that resulted in higher failure loads. Clinical significance The SA may reduce construct loading during abduction. The TB offers superior mechanical stability, potentially reducing long‐term degradation from cyclic loading.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Colorado State University, Veterinary Teaching Hospital, Fort Collins, Colorado, USA.
- Colorado State University, Orthopaedic Bioengineering Research Laboratory, Fort Collins, Colorado, USA.
- Clinique Vétérinaire equine de Grosbois, Marolles-en-Brie, France.
- Department of Clinical Sciences, Cornell University, College of Veterinary Medicine, Ithaca, New York, USA.
ORCID-Profile: Ulrika Marie, Arian Campos
Förderung
- Colorado State University College Research Council Colorado Racing Commission
Zitieren
APA
Ysebaert, M. P., Johnson, J., Marie, U., Campos, A., Verchrerin, A., Ducharme, N. G., Rossignol, F., & Luedke, L. K. (2026). Biomechanical testing of three constructs for prosthetic laryngoplasty in horses demonstrates advantages of differing metallic implants in the arytenoid cartilage. Veterinary Surgery. https://doi.org/10.1111/vsu.14328
Vancouver
Ysebaert MP, Johnson J, Marie U, Campos A, Verchrerin A, Ducharme NG, et al. Biomechanical testing of three constructs for prosthetic laryngoplasty in horses demonstrates advantages of differing metallic implants in the arytenoid cartilage. Veterinary Surgery. 2026. doi:10.1111/vsu.14328
BibTeX
@article{Ysebaert2026,
author = {Ysebaert, Machiel P and Johnson, James and Marie, Ulrika and Campos, Arian and Verchrerin, Anouk and Ducharme, Norm G and Rossignol, Fabrice and Luedke, Lauren K},
title = {Biomechanical testing of three constructs for prosthetic laryngoplasty in horses demonstrates advantages of differing metallic implants in the arytenoid cartilage},
journal = {Veterinary Surgery},
year = {2026},
doi = {10.1111/vsu.14328}
}
EUVIMED