Equine laryngoplasty: Effects of three anchoring techniques in the muscular process and three positions for suture implantation in the cricoid cartilage
Veterinary Surgery · 2024-10 · 53 (7) · 1185-1195
DOI: 10.1111/vsu.14108 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, online erschienen am 24.05.2024. Verfasst von Ulrika Maire und 4 weiteren Autor:innen. Beteiligte Einrichtung: Grosbois Equine Clinic, Paris, France. Hauptthemen laut MEDLINE: Laryngoplasty, Cricoid Cartilage, Suture Techniques, Cadaver. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Objective
To compare the effects of three anchoring techniques in the muscular process and three positions of laryngoplasty suture implantation in the cricoid cartilage on abduction of the arytenoid cartilage and interaction with the cricoarytenoid dorsalis (CAD) muscle compartments. Study design Experimental study. Sample population Twenty‐two cadaveric equine larynges.
Methods
Three implantation techniques were assessed in the left muscular process. They were the use of a titanium corkscrew (CS), a standard caudal passage using a Jamshidi needle (JCa), and a standard cranial passage using a Jamshidi needle (JCr). Each was assessed in combination with three caudal locations in the cricoid cartilage (right, left, and left lateral). Each suture combination was tightened to submaximal abduction (Dixon grade 2). Force on the suture, degree of larynx caudal rotation, and CAD muscle indentation were evaluated.
Results
The force required for optimal arytenoid cartilage abduction was lower ( p < .01) for constructs involving a CS (7.45 ± 4 N). The CS also resulted in lower ( p < .01) CAD muscle indentation (2.01 ± 1.25 mm) and less larynx rotation (9 ± 3.87°; adjusted p < .05).
Conclusion
When inserted into the muscular process at the CAD tendon insertion point, the biomechanical properties of the CS reduced the force required for optimal arytenoid cartilage abduction. The CS also minimized interference with the CAD muscle compartments and reduced caudal displacement of the left arytenoid cartilage when it was under suture tension. Clinical significance The CS implantation avoided larynx deformation and muscle interaction, offering the possibility to combine a nerve graft and laryngoplasty as a treatment for recurrent laryngeal neuropathy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Grosbois Equine Clinic, Paris, France.
- College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.
ORCID-Profile: Ulrika Maire, Ariane Campos Schweitzer
Zitieren
APA
Maire, U., Ducharme, N. G., Rossignol, A., Campos Schweitzer, A., & Rossignol, F. (2024). Equine laryngoplasty: Effects of three anchoring techniques in the muscular process and three positions for suture implantation in the cricoid cartilage. Veterinary Surgery, 53(7), 1185-1195. https://doi.org/10.1111/vsu.14108
Vancouver
Maire U, Ducharme NG, Rossignol A, Campos Schweitzer A, Rossignol F. Equine laryngoplasty: Effects of three anchoring techniques in the muscular process and three positions for suture implantation in the cricoid cartilage. Veterinary Surgery. 2024;53(7):1185-1195. doi:10.1111/vsu.14108
BibTeX
@article{Maire2024,
author = {Maire, Ulrika and Ducharme, Norm G and Rossignol, Anthony and Campos Schweitzer, Ariane and Rossignol, Fabrice},
title = {Equine laryngoplasty: Effects of three anchoring techniques in the muscular process and three positions for suture implantation in the cricoid cartilage},
journal = {Veterinary Surgery},
year = {2024},
volume = {53},
number = {7},
pages = {1185--1195},
doi = {10.1111/vsu.14108}
}
EUVIMED