EUVIMEDEUVIMED entdecken
Crossref

Accuracy and safety of two landmark‐guided techniques for arthrocentesis and intra‐articular injection of the shoulder in dogs

Brónach McClean iD, Turlough P McNally, Antonio Pozzi, Richard Evans, Laura C Cuddy iD

Veterinary Surgery · 2025

DOI: 10.1111/vsu.14218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Brónach McClean und 4 weiteren Autor:innen. Beteiligte Einrichtung: Veterinary Specialists Ireland, Summerhill, Ireland. Hauptthemen laut MEDLINE: Arthrocentesis, Shoulder Joint. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Veterinary Specialists Ireland Resident Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the accuracy and safety of two landmark‐guided techniques for shoulder arthrocentesis and injection. Study design Ex vivo prospective study. Animals A total of 36 paired canine cadaver forelimbs.

Methods

An electronic survey was used to assess the prevalence of injection technique amongst surgeons in clinical practice. Thoracic limbs were randomized to technique for shoulder arthrocentesis and injection (subacromial [SA], n = 18, or supratubercular [ST], n = 18). Repositions, attempts, and the acquisition of synovial fluid was recorded. After the needle was placed, contrast was injected into the joint to determine accuracy of position. The radiographic presence of intra‐articular contrast was judged as an accurate injection. Shoulders were disarticulated and India ink assay performed to assess for iatrogenic articular cartilage injury (IACI).

Results

Both SA and ST techniques were not accurate. Completely accurate injection was identified in 50% SA and 44% ST ( p = .80). IACI was identified in 50% SA versus 11% ST ( p = .027). There were no significant differences in repositions, attempts, presence of synovial fluid ( p = .5, p = .6, p = .7).

Conclusion

Landmark‐guided shoulder injections performed via SA and ST approaches in cadaveric dog shoulders are overall inaccurate. If performing landmark‐guided shoulder injection, ST technique carries a lower risk of IACI than SA in cadaveric shoulders. Clinical significance Landmark‐guided shoulder injections are inaccurate in dogs and may result in treatment failure. A ST approach may be considered preferable due to the lower risk of cartilage damage. Future studies should assess ultrasound‐guided techniques to improve accuracy and safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArthrocentesisShoulder JointAnimalsDogsInjections, Intra-ArticularCadaverProspective StudiesForelimb

Autor:innen und Institutionen

  • Veterinary Specialists Ireland, Summerhill, Ireland.
  • Vetsuisse Faculty Zürich, Zürich, Switzerland.
  • University of Minnesota, Minneapolis, Minnesota, USA.

ORCID-Profile: Brónach McClean, Laura C Cuddy

Förderung

  • Veterinary Specialists Ireland Resident Research Fund

Zitieren

APA

McClean, B., P McNally, T., Pozzi, A., Evans, R., & C Cuddy, L. (2025). Accuracy and safety of two landmark‐guided techniques for arthrocentesis and intra‐articular injection of the shoulder in dogs. Veterinary Surgery. https://doi.org/10.1111/vsu.14218

Vancouver

McClean B, P McNally T, Pozzi A, Evans R, C Cuddy L. Accuracy and safety of two landmark‐guided techniques for arthrocentesis and intra‐articular injection of the shoulder in dogs. Veterinary Surgery. 2025. doi:10.1111/vsu.14218

BibTeX
@article{McClean2025,
  author = {McClean, Brónach and P McNally, Turlough and Pozzi, Antonio and Evans, Richard and C Cuddy, Laura},
  title = {Accuracy and safety of two landmark‐guided techniques for arthrocentesis and intra‐articular injection of the shoulder in dogs},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.14218}
}
Kostenlos starten →