Evaluation of three acetabular measurement methods for total hip replacement in dogs
Veterinary Surgery · 2025
DOI: 10.1111/vsu.14190 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Jordan N Wilson und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Veterinary Medicine, William R Prichard Veterinary Medical Teaching Hospital, University of California Davis, Davis, California, USA. Hauptthemen laut MEDLINE: Acetabulum, Arthroplasty, Replacement, Hip, Dog Diseases, Hip Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To compare three measurement methods for acetabular sizing and evaluate the influence of osteoarthritis (OA) on the accuracy of measurements. Study design Observational study. Sample Radiographic images of 73 hip joints from 60 dogs with cementless cups.
Methods
Radiographs were anonymized and measured independently by three observers. One observer measured 12 sets of radiographs three times. A best‐fit acetabular circle (AC) and cranial‐caudal acetabular line (AL) were measured on ventral‐dorsal (VD) radiographic view and open leg lateral (OLL) view. A best‐fit femoral head circle (FHC) was measured on VD, OLL, and craniocaudal horizontal beam (CCHB) views. Two observers scored the OA in each hip joint. Intra‐ and interobserver consistency and repeatability and bias relative to implanted cup size were calculated and analyzed.
Results
Intraobserver consistency and repeatability were excellent for all measurements. Interobserver consistency was excellent (ICC > 0.9) for AC VD and AC OLL and was good (0.75 < ICC ≤ 0.9) for all other methods. Bias was small for AC and AL measurements (range, −0.46 to 0.45 mm) and large for FHC measurements (−3.58 to −2.42 mm). OA score significantly influenced bias for all acetabular measurement methods ( p < 0.05).
Conclusion
All acetabular measurement methods were highly consistent within an observer. Interobserver consistency was highest for AC VD and AC OLL . FHC measurements underestimated cup size. Higher OA scores decreased the accuracy of all acetabular measurement methods. Clinical significance Superimposing a circle on the acetabulum seen on VD radiographic view accurately measures the acetabulum before cementless cup placement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Veterinary Medicine, William R Prichard Veterinary Medical Teaching Hospital, University of California Davis, Davis, California, USA.
- Department of Veterinary Surgical and Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
- School of Veterinary Medicine, JD Wheat Veterinary Orthopedic Research Laboratory, University of California-Davis, Davis, California, USA.
ORCID-Profile: Barbro Filliquist, Denis J Marcellin-Little
Zitieren
APA
Wilson, J. N., Filliquist, B., Garcia, T. C., & Marcellin-Little, D. J. (2025). Evaluation of three acetabular measurement methods for total hip replacement in dogs. Veterinary Surgery. https://doi.org/10.1111/vsu.14190
Vancouver
Wilson JN, Filliquist B, Garcia TC, Marcellin-Little DJ. Evaluation of three acetabular measurement methods for total hip replacement in dogs. Veterinary Surgery. 2025. doi:10.1111/vsu.14190
BibTeX
@article{Wilson2025,
author = {Wilson, Jordan N and Filliquist, Barbro and Garcia, Tanya C and Marcellin-Little, Denis J},
title = {Evaluation of three acetabular measurement methods for total hip replacement in dogs},
journal = {Veterinary Surgery},
year = {2025},
doi = {10.1111/vsu.14190}
}
EUVIMED