Gastrointestinal thickness, duration, and leak pressure of five intestinal anastomosis techniques in cats
Veterinary Surgery · 2024
DOI: 10.1111/vsu.14043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Jackson E Sanders und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA. Hauptthemen laut MEDLINE: Intestines, Suture Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: University of Florida Small Animal Clinical Sciences Research Grant.
Abstract (Originalsprache)
Objective
To compare time to construct completion and resistance to leakage for five intestinal anastomosis techniques in cats and to report normal feline gastrointestinal thickness. Study design Experimental study. Sample population Grossly normal intestinal segments ( n = 120) from 10 fresh cat cadavers.
Methods
A total of 8 cm segments of fresh feline cadaveric intestine were collected, and mural thickness was recorded. Segments were randomly allocated between a control group ( n = 20 segments) and five treatment groups (20 segments/group with 2 segments/construct = 10 constructs per group): (1) hand‐sewn anastomosis – simple interrupted (HSA‐SI), (2) hand‐sewn anastomosis – simple continuous (HSA‐SC), (3) functional end‐to‐end stapled anastomosis (FEESA), (4) functional end‐to‐end stapled anastomosis with oversew (FEESA‐O), (5) skin stapled anastomosis (SS). Time to construct completion, leakage location, initial leak pressure (ILP), and maximum intraluminal pressure (MIP) were compared.
Results
Mean mural thickness ± SD (mm) for the stomach, duodenum, jejunum, and ileum were 1.66 ± 0.28, 2.05 ± 0.18, 2.28 ± 0.30, and 2.11 ± 0.39, respectively. ILPs (mean ± SD) for HSA‐SI (165 ± 122 mmHg), HSA‐SC (149 ± 83), FEESA‐O (63 ± 25, FEESA (84 ± 59), SS (77 ± 56), and control segments (>500) were compared. There was no statistically significant difference in ILP ( p > .08) or MIP ( p > .084) between any treatment groups. Nonoversewn FEESAs were 2.4 times faster to perform compared to oversewn FEESA and SS groups, and 4.7 times faster than HSA ( p < .001).
Conclusion
All anastomosis techniques provide resistance to leakage that is supraphysiological to that of the normal maximum intraluminal pressure. HSA take longer to complete than stapled anastomoses. Clinical significance All anastomotic techniques may be appropriate in cats. Hand‐sewn anastomoses result in a longer surgical time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA.
- Department of Statistics, College of Liberal Arts and Sciences University of Florida, Gainesville, Florida, USA.
Förderung
- University of Florida Small Animal Clinical Sciences Research Grant
Zitieren
APA
Sanders, J. E., Regier, P. J., Waln, M., & Colee, J. (2024). Gastrointestinal thickness, duration, and leak pressure of five intestinal anastomosis techniques in cats. Veterinary Surgery. https://doi.org/10.1111/vsu.14043
Vancouver
Sanders JE, Regier PJ, Waln M, Colee J. Gastrointestinal thickness, duration, and leak pressure of five intestinal anastomosis techniques in cats. Veterinary Surgery. 2024. doi:10.1111/vsu.14043
BibTeX
@article{Sanders2024,
author = {Sanders, Jackson E and Regier, Penny J and Waln, Monica and Colee, James},
title = {Gastrointestinal thickness, duration, and leak pressure of five intestinal anastomosis techniques in cats},
journal = {Veterinary Surgery},
year = {2024},
doi = {10.1111/vsu.14043}
}
EUVIMED