Ex vivo evaluation of a technique for equine jejunocecal anastomosis using radiofrequency thermofusion and a Cushing oversew
Veterinary Surgery · 2023
DOI: 10.1111/vsu.13946 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2023. Verfasst von Marco Gandini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Sciences, University of Turin, Turin, Italy. Hauptthemen laut MEDLINE: Intestine, Small, Suture Techniques. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
Objective
To describe a technique for a side‐to‐side jejunocecal anastomosis in horses using radiofrequency thermofusion (TF) of the intestines supported by a Cushing oversew and to compare this anastomosis to handsewn and stapled techniques. Study design Ex vivo study. Sample population Intestinal tracts from 24 slaughtered horses.
Methods
A radiofrequency device was used to perform a jejunocecal anastomosis (Group RFA). The construction time and bursting pressure of this construct were compared with those of a hand‐sewn double layer (Group HS) and stapled anastomoses (Group ST) without oversew of the staple line. Histology was also performed for the TF anastomoses to evaluate the extent of the thermal damage.
Results
The median (range) construction time (min) for the TF (15.8 [14.4‐16.8]) was not significantly different from that for the HS (25.5 [24.2‐26.3]) and ST (10.8 [9.7‐12.5]) groups ( p = .07). The construction time for ST was shorter than that for HS group ( p < .001). The average (standard deviation) bursting pressure (mmHg) for HS (153.1 +/− 17.5) was higher than that for RFA (76 +/− 15) and ST groups (48 +/− 13; p < .001). The bursting pressure of the RFA was higher than that of the ST anastomoses ( p = .001). The thermal damage caused by the device was within the suture oversew in the deeper layers, whereas it extended a few mm beyond the suture line in the serosa.
Conclusion
Radiofrequency assisted anastomoses provide similar construction times to current techniques and have a higher bursting pressure than ST anastomoses. Clinical significance Radiofrequency‐assisted anastomoses with a suture oversew demonstrated comparable bursting pressures to ST anastomoses. The use of the radiofrequency device on the intestine is extra label and causes serosal tissue damage, which may increase the risk of adhesions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Veterinary Sciences, University of Turin, Turin, Italy.
ORCID-Profile: Anna Cerullo
Zitieren
APA
Gandini, M., Cerullo, A., Gallo, L., Iussich, S., Minoli, L., & Giusto, G. (2023). Ex vivo evaluation of a technique for equine jejunocecal anastomosis using radiofrequency thermofusion and a Cushing oversew. Veterinary Surgery. https://doi.org/10.1111/vsu.13946
Vancouver
Gandini M, Cerullo A, Gallo L, Iussich S, Minoli L, Giusto G. Ex vivo evaluation of a technique for equine jejunocecal anastomosis using radiofrequency thermofusion and a Cushing oversew. Veterinary Surgery. 2023. doi:10.1111/vsu.13946
BibTeX
@article{Gandini2023,
author = {Gandini, Marco and Cerullo, Anna and Gallo, Livio and Iussich, Selina and Minoli, Lucia and Giusto, Gessica},
title = {Ex vivo evaluation of a technique for equine jejunocecal anastomosis using radiofrequency thermofusion and a Cushing oversew},
journal = {Veterinary Surgery},
year = {2023},
doi = {10.1111/vsu.13946}
}
EUVIMED