Comparison of three‐dimensional printed patient‐specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model
Veterinary Surgery · 2024
DOI: 10.1111/vsu.13968 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Adam Townsend und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgical Sciences and Comparative Orthopedic Research Laboratory, School of Veterinary Medicine, University of Wisconsin-Madison, Madis…. Hauptthemen laut MEDLINE: Osteotomy, Radius. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: American College of Veterinary Surgeons Foundation, Companion Animal Fund-UW-Madison.
Abstract (Originalsprache)
Objective
To compare the accuracy of three‐dimensional (3D) printed patient‐specific guide (PSG) with a freehand (FH) approach for radial osteotomies in ex vivo normal dogs. Study design Experimental study. Animals Twenty four ex vivo thoracic limb pairs from normal beagle dogs.
Methods
Computed tomography (CT) images were collected preoperatively and postoperatively. Three osteotomies tested (n = 8/group) were: (1) uniplanar 30° frontal plane wedge ostectomy, (2) oblique plane (30° frontal, 15° sagittal) wedge ostectomy, and (3) single oblique plane osteotomy (SOO, 30° frontal, 15° sagittal, and 30° external). Limb pairs were randomized to a 3D PSG or FH approach. The resultant osteotomies were compared with virtual target osteotomies by surface shape‐matching postoperative to the preoperative radii.
Results
The mean ± standard deviation osteotomy angle deviation for all 3D PSG osteotomies (2.8 ± 2.8°, range 0.11–14.1°) was less than for the FH osteotomies (6.4 ± 6.0°, range 0.03–29.7°). No differences were found for osteotomy location in any group. In total, 84% of 3D PSG osteotomies were within 5° deviance from the target compared to 50% of freehand osteotomies.
Conclusion
Three‐dimensional PSG improved FH accuracy of osteotomy angle in select planes and the most complex osteotomy orientation in a normal ex vivo radial model. Clinical significance Three‐dimensional PSGs provided more consistent accuracy, which was most notable in complex radial osteotomies. Future work is needed to investigate guided osteotomies in dogs with antebrachial bone deformities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Surgical Sciences and Comparative Orthopedic Research Laboratory, School of Veterinary Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Division of Surgery, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern, Bern, Switzerland.
- Vet 3D, Coventry, UK.
- Department of Biostatistics and Medical Informatics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Veterinary Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA.
ORCID-Profile: Jason Bleedorn
Förderung
- American College of Veterinary Surgeons Foundation
- Companion Animal Fund-UW-Madison
Zitieren
APA
Townsend, A., Guevar, J., Oxley, B., Hetzel, S., & Bleedorn, J. (2024). Comparison of three‐dimensional printed patient‐specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model. Veterinary Surgery. https://doi.org/10.1111/vsu.13968
Vancouver
Townsend A, Guevar J, Oxley B, Hetzel S, Bleedorn J. Comparison of three‐dimensional printed patient‐specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model. Veterinary Surgery. 2024. doi:10.1111/vsu.13968
BibTeX
@article{Townsend2024,
author = {Townsend, Adam and Guevar, Julien and Oxley, Bill and Hetzel, Scott and Bleedorn, Jason},
title = {Comparison of three‐dimensional printed patient‐specific guides versus freehand approach for radial osteotomies in normal dogs: Ex vivo model},
journal = {Veterinary Surgery},
year = {2024},
doi = {10.1111/vsu.13968}
}