EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

CT‐Based Reference Ranges for Canine Pyloric Thickness: Influence of Body Size and Normalization With Aortic Diameter

Jihoon Lee iD, Danbee Kwon iD, Sungsoo Kim iD, Ilyong Yoon, Kichang Lee iD, Hakyoung Yoon iD

Veterinary Radiology & Ultrasound · 2026

DOI: 10.1111/vru.70209 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Veterinary Radiology & Ultrasound, 2026. Verfasst von Jihoon Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medical Imaging, College of Veterinary Medicine, Jeonbuk National University, Iksan-si, Jeollabuk-do, Republic of Korea. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Pylorus, Aorta. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pyloric wall thickness reflects pyloric pathology. Prior related studies included small samples and did not consistently measure perpendicular to the pyloric axis. This multicenter retrospective study established body‐weight (BW)‐specific computed tomography (CT) reference ranges for pyloric thickness, measured in both cross‐sectional and transverse planes, in clinically normal dogs and evaluated relationships with BW, age, breed, and sex. Multiplanar reconstruction (MPR) was used to obtain a true cross‐sectional plane, and the transverse plane was used for practicality. CT images of 229 dogs were analyzed to measure pyloric thickness and calculate the pyloric thickness‐to‐aortic diameter (P/Ao) ratio. Consistent differences were observed between planes. Pyloric thickness showed a positive correlation with BW, with significant differences across BW groups. No significant association was found with age, nor based on neutering status, nor among breeds with similar BW. A minor difference between sexes was observed only in the transverse plane, likely reflecting oblique slicing. In the cross‐sectional plane, mean (±standard deviation [SD]) pyloric thickness was 3.61 ± 0.76, 4.21 ± 0.87, 5.10 ± 1.14, and 6.93 ± 1.18 mm for dogs weighing

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedPylorusAortaAnimalsDogsReference ValuesFemaleMaleBody SizeRetrospective StudiesBody Weight

Stichwörter der Autor:innen

body‐weight indexcaninegastrointestinal wallnormal reference rangepyloric measurement

Autor:innen und Institutionen

  • Department of Veterinary Medical Imaging, College of Veterinary Medicine, Jeonbuk National University, Iksan-si, Jeollabuk-do, Republic of Korea.
  • Bundang Leaders Animal Medical Center, Seongnam-si, Gyeonggi-do, Republic of Korea.
  • VIP Animal Medical Center, Seoul, Republic of Korea.
  • NEL Animal Medical Foundation, Anyang-si, Gyeonggi-do, Republic of Korea.

ORCID-Profile: Jihoon Lee, Danbee Kwon, Sungsoo Kim, Kichang Lee, Hakyoung Yoon

Zitieren

APA

Lee, J., Kwon, D., Kim, S., Yoon, I., Lee, K., & Yoon, H. (2026). CT‐Based Reference Ranges for Canine Pyloric Thickness: Influence of Body Size and Normalization With Aortic Diameter. Veterinary Radiology & Ultrasound. https://doi.org/10.1111/vru.70209

Vancouver

Lee J, Kwon D, Kim S, Yoon I, Lee K, Yoon H. CT‐Based Reference Ranges for Canine Pyloric Thickness: Influence of Body Size and Normalization With Aortic Diameter. Veterinary Radiology & Ultrasound. 2026. doi:10.1111/vru.70209

BibTeX
@article{Lee2026,
  author = {Lee, Jihoon and Kwon, Danbee and Kim, Sungsoo and Yoon, Ilyong and Lee, Kichang and Yoon, Hakyoung},
  title = {CT‐Based Reference Ranges for Canine Pyloric Thickness: Influence of Body Size and Normalization With Aortic Diameter},
  journal = {Veterinary Radiology & Ultrasound},
  year = {2026},
  doi = {10.1111/vru.70209}
}
Kostenlos starten →