EUVIMEDEUVIMED entdecken
Crossref

Effectiveness of body size stratification for patient exposure optimization in Computed Tomography

Francesca De Monte, Sonia Sapignoli, Anna Laura Cortinovis, Antonio Di Maggio, Margherita Nardin, Enrico Pizzirani, Elena Scagliori, Alessandro Volpe, Marta Paiusco, Antonella Roggio

European Journal of Radiology · 2023

DOI: 10.1016/j.ejrad.2023.110804 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2023. Verfasst von Francesca De Monte und 9 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy. Electronic address: francesca.demonte@iov.veneto.it. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Water. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Ministero della Salute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To establish size-dependent DRL and to estimate the effectiveness of the size-dependent DRLs over size-independent DRLs for a CT exposure optimization process. METHODS: The study included 16,933 adult CT body examinations of the most common CT protocols. Acquisitions were included following an image quality assessment. Patients were grouped into five different classes by means of the water equivalent diameter (Dw): 21 ≤ Dw 0.7). For small and large patients size-independent approach fails to identify as sub-optimal around 20 % of the acquisition (MCC≪0.2). CONCLUSIONS: It was proven by means of the confusion matrix and MCC metric that stratifying DRLs by patient size, size-dependent DRL can be a powerful strategy in order to improve the dose optimization process shown that a size-independent DRL fails to identify sub-optimal examinations for small and large patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedWaterAdultHumansRadiation DosageReference ValuesBody Size

Stichwörter der Autor:innen

CT dose indexConfusion matrixDiagnostic Reference LevelRadiation dose tracking system

Substanzen

Water

Autor:innen und Institutionen

  • Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy. Electronic address: francesca.demonte@iov.veneto.it.
  • Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy. Electronic address: sonia.sapignoli@iov.veneto.it.
  • University of Padua, Padua, Italy. Electronic address: annaelle.cortinovis@gmail.com.
  • Radiology Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy. Electronic address: antonio.dimaggio@iov.veneto.it.
  • Radiology Unit, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy. Electronic address: margherita.nardin@iov.veneto.it.
  • Radiology Unit, University-Hospital of Padua, Padua, Italy. Electronic address: enrico.pizzirani@aopd.veneto.it.

Förderung

  • Ministero della Salute

Zitieren

APA

De Monte, F., Sapignoli, S., Laura Cortinovis, A., Di Maggio, A., Nardin, M., Pizzirani, E., Scagliori, E., Volpe, A., Paiusco, M., & Roggio, A. (2023). Effectiveness of body size stratification for patient exposure optimization in Computed Tomography. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2023.110804

Vancouver

De Monte F, Sapignoli S, Laura Cortinovis A, Di Maggio A, Nardin M, Pizzirani E, et al. Effectiveness of body size stratification for patient exposure optimization in Computed Tomography. European Journal of Radiology. 2023. doi:10.1016/j.ejrad.2023.110804

BibTeX
@article{DeMonte2023,
  author = {De Monte, Francesca and Sapignoli, Sonia and Laura Cortinovis, Anna and Di Maggio, Antonio and Nardin, Margherita and Pizzirani, Enrico and Scagliori, Elena and Volpe, Alessandro and Paiusco, Marta and Roggio, Antonella},
  title = {Effectiveness of body size stratification for patient exposure optimization in Computed Tomography},
  journal = {European Journal of Radiology},
  year = {2023},
  doi = {10.1016/j.ejrad.2023.110804}
}
Kostenlos starten →