EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Cone‐beam computed tomography produces images of numerically comparable diagnostic quality for bone and inferior quality for soft tissues compared with fan‐beam computed tomography in cadaveric equine metacarpophalangeal joints

Holly L Stewart iD, Jeffrey H Siewerdsen iD, Kurt T Selberg, Kathryn W Bills iD, Christopher E Kawcak

Veterinary Radiology & Ultrasound · 2023-11 · 64 (6) · 1033-1036

DOI: 10.1111/vru.13309 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Radiology & Ultrasound, online erschienen am 10.11.2023. Verfasst von Holly L Stewart und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, New Bolton Center, University of Pennsylvania, Kennett Square, Pennsylvania, USA. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Horse Diseases. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cone‐beam computed tomography (CBCT) is an emerging modality for imaging of the equine patient. The objective of this prospective, descriptive, exploratory study was to assess visualization tasks using CBCT compared with conventional fan‐beam CT (FBCT) for imaging of the metacarpophalangeal joint in equine cadavers. Satisfaction scores were numerically excellent with both CBCT and FBCT for bone evaluation, and FBCT was numerically superior for soft tissue evaluation. Preference tests indicated FBCT was numerically superior for soft tissue evaluation, while preference test scoring for bone was observer‐dependent. Findings from this study can be used as background for future studies evaluating CBCT image quality in live horses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedHorse DiseasesAnimalsHorsesProspective StudiesCone-Beam Computed TomographyBone and BonesMetacarpophalangeal JointCadaver

Stichwörter der Autor:innen

fetlockhorseimage qualityvisualization task

Autor:innen und Institutionen

  • Department of Clinical Studies, New Bolton Center, University of Pennsylvania, Kennett Square, Pennsylvania, USA.
  • Department of Imaging Physics, Neurosurgery, and Radiation Physics, The University of Texas M.D. Anderson Cancer Center, Houston, Texas, USA.
  • Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, Colorado, USA.
  • Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA.

ORCID-Profile: Holly L Stewart, Jeffrey H Siewerdsen, Kathryn W Bills

Zitieren

APA

Stewart, H. L., Siewerdsen, J. H., Selberg, K. T., Bills, K. W., & Kawcak, C. E. (2023). Cone‐beam computed tomography produces images of numerically comparable diagnostic quality for bone and inferior quality for soft tissues compared with fan‐beam computed tomography in cadaveric equine metacarpophalangeal joints. Veterinary Radiology & Ultrasound, 64(6), 1033-1036. https://doi.org/10.1111/vru.13309

Vancouver

Stewart HL, Siewerdsen JH, Selberg KT, Bills KW, Kawcak CE. Cone‐beam computed tomography produces images of numerically comparable diagnostic quality for bone and inferior quality for soft tissues compared with fan‐beam computed tomography in cadaveric equine metacarpophalangeal joints. Veterinary Radiology & Ultrasound. 2023;64(6):1033-1036. doi:10.1111/vru.13309

BibTeX
@article{Stewart2023,
  author = {Stewart, Holly L and Siewerdsen, Jeffrey H and Selberg, Kurt T and Bills, Kathryn W and Kawcak, Christopher E},
  title = {Cone‐beam computed tomography produces images of numerically comparable diagnostic quality for bone and inferior quality for soft tissues compared with fan‐beam computed tomography in cadaveric equine metacarpophalangeal joints},
  journal = {Veterinary Radiology & Ultrasound},
  year = {2023},
  volume = {64},
  number = {6},
  pages = {1033--1036},
  doi = {10.1111/vru.13309}
}
Kostenlos starten →