EUVIMEDAtklāt EUVIMED
Crossref

Difference in Collection Times, Blood Gas Variables, and Atelectasis Between Two Arterial Sampling Methods in Dogs

Kento Sakai, Seijirow Goya, Chieko Ishikawa, Naoko Shiozawa, Tomohiro Nakayama

Journal of Veterinary Emergency and Critical Care · 2026

DOI: 10.1111/vec.70171 ↗

At a glance

Journal article in Journal of Veterinary Emergency and Critical Care, 2026. Written by Kento Sakai and 4 co-authors. Institution: Laboratory of Veterinary Radiology, Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Fujisawa, Kanagawa, Japan. Major MEDLINE topics: Blood Gas Analysis, Blood Specimen Collection, Pulmonary Atelectasis. 26 references.

AbstraktsSubjectsBibliogrāfiskie datiCiteRelated studies

Abstract (original language)

Objective

To assess how two different arterial blood sampling methods, from the femoral artery (FA) or the dorsal pedal artery (DPA), influence the collection time, gas variables, and pulmonary atelectasis on computed tomography (CT) under sedation.

Design

Experimental, single‐blind, crossover study.

Setting

Veterinary university research facility. Animals Eight healthy Beagle dogs.

Interventions

Butorphanol was administered subcutaneously before sampling. Arterial blood samples were collected using the FA or DPA in lateral or sternal recumbency, respectively, followed by hemostasis. Medetomidine was then administered intravenously, and thoracic CT was performed under sedation. Dogs remained in the same position throughout the procedure, from blood collection to completion of the thoracic CT scan. All variables were tested for normality using the Kolmogorov–Smirnov test. CT values were analyzed using the Student's t ‐test. PaO 2 and sampling time were analyzed using the Wilcoxon signed‐rank test. Statistical significance was set at p < 0.05. Measurements and Main Results Collection time using the DPA method (47.5 s [31–69 s]) was significantly shorter than the FA method (94.5 s [65–126 s]) ( p = 0.0156). No significant differences in gas variables were observed between the two methods. The mean CT values that indicated atelectasis in the cranial ( p < 0.01), middle ( p = 0.0107), and caudal ( p = 0.0146) lung lobes using the FA method were significantly higher than those using the DPA method.

Conclusions

Blood collection was faster using the DPA method than the FA method, and even brief lateral recumbency during the FA method is associated with atelectasis.

Subjects

MeSH terms (MEDLINE)

Blood Gas AnalysisBlood Specimen CollectionPulmonary AtelectasisAnimalsDogsCross-Over StudiesMaleTime FactorsFemaleFemoral ArterySingle-Blind MethodTomography, X-Ray Computed

Author keywords

arterial blood gas analysiscaninehypoxialung attenuation

Authors and institutions

  • Laboratory of Veterinary Radiology, Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Fujisawa, Kanagawa, Japan.
  • Nihon University Animal Medical Center, Fujisawa, Kanagawa, Japan.

Cite

APA

Sakai, K., Goya, S., Ishikawa, C., Shiozawa, N., & Nakayama, T. (2026). Difference in Collection Times, Blood Gas Variables, and Atelectasis Between Two Arterial Sampling Methods in Dogs. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.70171

Vancouver

Sakai K, Goya S, Ishikawa C, Shiozawa N, Nakayama T. Difference in Collection Times, Blood Gas Variables, and Atelectasis Between Two Arterial Sampling Methods in Dogs. Journal of Veterinary Emergency and Critical Care. 2026. doi:10.1111/vec.70171

BibTeX
@article{Sakai2026,
  author = {Sakai, Kento and Goya, Seijirow and Ishikawa, Chieko and Shiozawa, Naoko and Nakayama, Tomohiro},
  title = {Difference in Collection Times, Blood Gas Variables, and Atelectasis Between Two Arterial Sampling Methods in Dogs},
  journal = {Journal of Veterinary Emergency and Critical Care},
  year = {2026},
  doi = {10.1111/vec.70171}
}
Start for free →