Comparison of SpO 2 /FiO 2 and PaO 2 /FiO 2 Ratios in Mechanically Ventilated Dogs
Journal of Veterinary Emergency and Critical Care · 2025
DOI: 10.1111/vec.70063 ↗At a glance
Vergleichsstudie in Journal of Veterinary Emergency and Critical Care, 2025. Written by Gabriela L Rivas and 5 co-authors. Institution: Department of Small Animal Clinical Sciences, Texas A&M School of Veterinary Medicine & Biomedical Sciences, College Station, Texas, USA. Major MEDLINE topics: Blood Gas Analysis, Oxygen, Oxygen Saturation, Respiration, Artificial. 42 references.
Abstract (original language)
Objective
To determine whether the SpO 2 /FiO 2 (SF) ratio correlates with the PaO 2 /FiO 2 (PF) ratio in mechanically ventilated dogs.
Design
Prospective, multicenter, longitudinal, observational study.
Setting
Private veterinary referral center and a veterinary medical teaching institution. Animals Thirty‐seven client‐owned dogs requiring mechanical ventilation between April 2021 and April 2023.
Interventions
None. Measurements and Main Results SpO 2 and FiO 2 values in mechanically ventilated dogs were recorded at the time of arterial blood gas sampling. SpO 2 values between 80% and 97%, PaO 2 , and FiO 2 were used to calculate and determine the relationship between SF and PF ratios. The weighted Spearman correlation coefficient between the ratios was 0.70 ( p < 0.0001), and the relationship between them was described by the following linear mixed model: SF = 0.50 × (PF) + 103. The linear model predicted that SF ratios of 153, 203, and 253 correspond with PF ratios of 100, 200, and 300, respectively. There was an adequate to outstanding discriminatory ability for SF to predict PF
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Small Animal Clinical Sciences, Texas A&M School of Veterinary Medicine & Biomedical Sciences, College Station, Texas, USA.
- Arizona Veterinary Emergency and Critical Care Center, Gilbert, Arizona, USA.
- Department of Veterinary Clinical Sciences, The Ohio State University Veterinary Medical Center, Columbus, Ohio, USA.
- Department of Clinical Sciences, North Carolina State University College of Veterinary Medicine, Raleigh, North Carolina, USA.
- Kaleidoscope Statistics, LLC, Athens, Georgia, USA.
- Department of Clinical Studies, University of Pennsylvania School of Veterinary Medicine, Philadelphia, Pennsylvania, USA.
ORCID profiles: Gabriela L Rivas, Jiwoong Her, Tereza Stastny
Cite
APA
Rivas, G. L., Her, J., Keys, D. A., Mattison, B. L., Caldwell, D. J., & Stastny, T. (2025). Comparison of SpO 2 /FiO 2 and PaO 2 /FiO 2 Ratios in Mechanically Ventilated Dogs. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.70063
Vancouver
Rivas GL, Her J, Keys DA, Mattison BL, Caldwell DJ, Stastny T. Comparison of SpO 2 /FiO 2 and PaO 2 /FiO 2 Ratios in Mechanically Ventilated Dogs. Journal of Veterinary Emergency and Critical Care. 2025. doi:10.1111/vec.70063
BibTeX
@article{Rivas2025,
author = {Rivas, Gabriela L and Her, Jiwoong and Keys, Deborah A and Mattison, Brandi L and Caldwell, Dana J and Stastny, Tereza},
title = {Comparison of SpO 2 /FiO 2 and PaO 2 /FiO 2 Ratios in Mechanically Ventilated Dogs},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2025},
doi = {10.1111/vec.70063}
}
EUVIMED