Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs
Journal of Veterinary Emergency and Critical Care · 2025
DOI: 10.1111/vec.13455 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Emergency and Critical Care, 2025. Verfasst von Pablo Alejandro Donati und 6 weiteren Autor:innen. Beteiligte Einrichtung: Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Cátedra de Anestesiología y Algiología, Buenos Aires, Argentina. Hauptthemen laut MEDLINE: Dog Diseases, Shock, Spleen, Ultrasonography, Doppler. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
Objective
To assess the splenic flow resistance index (RI) and its response to a fluid bolus in dogs showing circulatory abnormalities upon hospital admission.
Design
Prospective clinical study.
Setting
Veterinary referral hospital. Animals Nine dogs with circulatory shock and nine dogs without circulatory abnormalities.
Interventions
Dogs with circulatory abnormalities received an IV bolus of 30 mL/kg of balanced isotonic crystalloid fluid. Measurements and Main Results The splenic flow RI and the baseline aortic velocity–time integral of both groups of dogs were evaluated upon hospital admission. Measurements were repeated after the fluid bolus in dogs with circulatory shock. The Mann–Whitney U ‐test or the Wilcoxon rank sign test was used as appropriate. The median RI in dogs with circulatory shock was higher than that in dogs without hemodynamic disorders (median [interquartile range]: 0.64 [0.62–0.77] vs. 0.54 [0.51–0.54], P < 0.001). The best cutoff value to discriminate between the two groups was 0.61, with an area under the receiver operating characteristic curve of 1.00 (95% confidence interval [CI]: 1.00–1.00), a sensitivity of 100% (95% CI: 66.4–100), a specificity of 100% (95% CI: 66.4–100), a positive predictive value of 100% (95% CI: 66.4–100), and a negative predictive value of 100% (95% CI: 66.4–100). After fluid expansion, a significant decrease in the median splenic flow RI was observed (0.57 [0.54–0.71], P = 0.007 vs. basal).
Conclusions
The splenic flow RI may be a dependable tool for identifying circulatory shock in dogs and assessing their response to fluid therapy. Additional studies are required to evaluate the use of this index for the monitoring of organ perfusion, changes in cardiac output, and fluid responsiveness in critically ill dogs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Cátedra de Anestesiología y Algiología, Buenos Aires, Argentina.
- Cooperative Veterinary Intensive Care Unit (UCICOOP), Buenos Aires, Argentina.
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.
- Chair of Applied Pharmacology, Faculty of Medical Sciences, National University of La Plata, La Plata, Argentina.
ORCID-Profile: Pablo Alejandro Donati, Lisa Tarragona
Zitieren
APA
Donati, P. A., Otero, P. E., Tarragona, L., Tunesi, M., Flores, M. M., D Alotto, S., & Dubín, A. (2025). Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.13455
Vancouver
Donati PA, Otero PE, Tarragona L, Tunesi M, Flores MM, D Alotto S, et al. Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs. Journal of Veterinary Emergency and Critical Care. 2025. doi:10.1111/vec.13455
BibTeX
@article{Donati2025,
author = {Donati, Pablo Alejandro and Otero, Pablo E and Tarragona, Lisa and Tunesi, Marcela and Flores, Manuel Martín and D Alotto, Santiago and Dubín, Arnaldo},
title = {Splenic Doppler Resistance Index for Detection of Circulatory Shock in Dogs},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2025},
doi = {10.1111/vec.13455}
}
EUVIMED