The influence of haemorrhage and fluid resuscitation with either Plasma-Lyte A or Ringer’s Lactate in Beagle dogs under sevoflurane anaesthesia—part 1: Macrocirculation
Veterinary Anaesthesia and Analgesia · 2026
DOI: 10.1016/j.vaa.2026.101233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026. Verfasst von Federico Gianolli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Section of Anaesthesiology, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Fluid Therapy, Ringer's Lactate, Anesthetics, Inhalation, Hemorrhage. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Themen: Reanimation
Abstract (Originalsprache)
OBJECTIVE: To compare macrocirculatory effects of haemorrhage followed by fluid resuscitation with Plasma-Lyte A (PA) or Ringer's Lactate (RL) crystalloid solution in dogs under sevoflurane anaesthesia. STUDY DESIGN: Single-centre, randomised, blinded, experimental study. ANIMALS: A group of 12 adult, healthy, intact, purpose-bred Beagle dogs. METHODS: Dogs were instrumented under sevoflurane anaesthesia. Heart rate, cardiac output (CO), and mean arterial blood pressure (MAP) were measured at baseline, after removing 30 mL kg-1 of blood over 15 minutes [hypovolaemia (HV)], and after each of two boluses (B1 and B2) of either 10 mL kg-1 PA or RL administered intravenously over 10 minutes. Data were compared using a linear mixed model with group and time points as fixed factors and dogs as a random factor, and corrections for multiple comparisons. A p value < 0.05 was considered significant. RESULTS: There were no significant differences between treatments. Compared with HV, CO increased in both groups at B1: RL [0.57 (0.23-0.91) L minute-1 (estimated difference ± 95% confidence interval), p < 0.001] and PA [0.37 (0.03-0.7) L minute-1, p = 0.030], and at B2: RL [0.88 (0.54-1.2), p < 0.001] and PA [0.66 (0.23-0.91) L minute-1, p < 0.001]. The increase of MAP in RL was significant at B1 [15 (1-29) mmHg, p < 0.028] and B2 [16 (2-30) mmHg, p < 0.016] compared with HV, while MAP in PA was not significantly different at B1 [3 (-11 to 17) mmHg, p = 0.995] and B2 [4 (-9 to 18) mmHg, p = 0.943] compared with HV. CONCLUSIONS AND CLINICAL RELEVANCE: In this small experimental study, both fluids tested led to a clinically significant increase in CO. No consistent increase in MAP was observed across fluid types. Alterations in MAP should not be used as a surrogate for flow variables to assess fluid responsiveness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Section of Anaesthesiology, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
- Section of Anaesthesiology, Department of Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland. Electronic address: akutter@vetclinics.uzh.ch.
Zitieren
APA
Gianolli, F., Steblaj, B., Gruell, C. A., & Kutter, A. P. (2026). The influence of haemorrhage and fluid resuscitation with either Plasma-Lyte A or Ringer’s Lactate in Beagle dogs under sevoflurane anaesthesia—part 1: Macrocirculation. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2026.101233
Vancouver
Gianolli F, Steblaj B, Gruell CA, Kutter AP. The influence of haemorrhage and fluid resuscitation with either Plasma-Lyte A or Ringer’s Lactate in Beagle dogs under sevoflurane anaesthesia—part 1: Macrocirculation. Veterinary Anaesthesia and Analgesia. 2026. doi:10.1016/j.vaa.2026.101233
BibTeX
@article{Gianolli2026,
author = {Gianolli, Federico and Steblaj, Barbara and Gruell, Christina A and Kutter, Annette Pn},
title = {The influence of haemorrhage and fluid resuscitation with either Plasma-Lyte A or Ringer’s Lactate in Beagle dogs under sevoflurane anaesthesia—part 1: Macrocirculation},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2026},
doi = {10.1016/j.vaa.2026.101233}
}
EUVIMED