Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability
Veterinary Clinical Pathology · 2026-09 · 55 (3) · 272-286
DOI: 10.1111/vcp.70140 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Clinical Pathology, online erschienen am 09.09.2026. Verfasst von Yan-Ni Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Occupational Health and Toxicity Assessment, Guangxi Zhuang Autonomous Region Institute for the Prevention and Treatment of Occupationa…. Hauptthemen laut MEDLINE: Blood Specimen Collection. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Guangxi Zhuang Autonomous Region Health Department.
Abstract (Originalsprache)
Background
In laboratory practice, complete blood count (CBC) analysis is not always immediate, and underfilled or overfilled blood tubes may yield misleading results.
Objectives
To assess CBC stability in rats and rabbits over 24 h and determine the effect of under‐ or over‐filled tubes on alterations in the results, demonstrating which indices remain reliable under these conditions.
Methods
Blood was collected into EDTA‐K 2 vacuum tubes from rats (tubes: 0.5, 1.0, 1.5, 2.0 mL) and rabbits (tubes: 2.0, 2.5 mL). All tubes were stored at 4°C and analyzed at 0, 4, 8, and 24 h using a CBC analyzer.
Results
Statistically significant changes ( p < 0.05) were observed: In rats, white blood cell (WBC), neutrophil, lymphocyte, monocyte, red blood cell (RBC), hematocrit (HCT), and hemoglobin (Hb) counts were sensitive to blood sampling volume and decreased with smaller volumes. WBC, neutrophil, RBC, HCT, and platelet (PLT) counts showed no statistically significant change within 24 h. In rabbits, blood sampling volume and storage time independently influenced WBC, neutrophil, lymphocyte, and Hb counts. RBC, HCT, and PLT counts showed no statistically significant change within 8 h.
Conclusions
WBC, neutrophil, lymphocyte, RBC, HCT, and Hb are volume‐sensitive in rats and rabbits, whereas PLT counts are unaffected by volume. Therefore, blood samples with insufficient or excessive fill may still be used for PLT measurement, but results for the other indices are not recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Occupational Health and Toxicity Assessment, Guangxi Zhuang Autonomous Region Institute for the Prevention and Treatment of Occupational Disease, Nanning, China.
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, China.
- Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, China.
- Department of Molecular Pharmacology, Albert Einstein College of Medicine, New York, USA.
ORCID-Profile: Yue-Ming Jiang
Förderung
- Guangxi Zhuang Autonomous Region Health Department
Zitieren
APA
Huang, Y. N., Li, Y. L., Xie, Y. H., Ling, J. A., Chen, R. Z., Fu, S. W., Xie, J., Aschner, M., & Jiang, Y. M. (2026). Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability. Veterinary Clinical Pathology, 55(3), 272-286. https://doi.org/10.1111/vcp.70140
Vancouver
Huang YN, Li YL, Xie YH, Ling JA, Chen RZ, Fu SW, et al. Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability. Veterinary Clinical Pathology. 2026;55(3):272-286. doi:10.1111/vcp.70140
BibTeX
@article{Huang2026,
author = {Huang, Yan-Ni and Li, Yi-Ling and Xie, Yu-Han and Ling, Jian-An and Chen, Rui-Ze and Fu, Song-Wen and Xie, Jing and Aschner, Michael and Jiang, Yue-Ming},
title = {Stability of Complete Blood Count Parameters in Rats and Rabbits: Impact of Blood Sampling Volume and Storage Time on Analytical Reliability},
journal = {Veterinary Clinical Pathology},
year = {2026},
volume = {55},
number = {3},
pages = {272--286},
doi = {10.1111/vcp.70140}
}
EUVIMED