Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs
Veterinary Clinical Pathology · 2026-03 · 55 (1) · 23-29
DOI: 10.1111/vcp.70088 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Clinical Pathology, online erschienen am 07.03.2026. Verfasst von Erin M Phillips und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada. Hauptthemen laut MEDLINE: Dogs, Blood Coagulation Tests. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: OVC Pet Trust.
Abstract (Originalsprache)
Background
Thrombin generation assessment using calibrated automated thrombography (CAT) requires a standard volume of plasma (80 μL) and reagent (20 μL) run in triplicate. A CAT method using lower plasma and reagent volumes could benefit veterinary patients as it lowers the sampling burden in patients.
Objectives
To compare standard CAT methodology to a low plasma and low reagent volume CAT method in dogs.
Methods
Platelet‐poor plasma samples were obtained by direct jugular venipuncture in dogs with low ( n = 10), high ( n = 10), and normal ( n = 10) thrombin generation potential, recruited from a tertiary referral hospital. Method comparison was performed between standard CAT (80 μL plasma, 20 μL reagent‐ method 1) and low volume CAT (40 μL plasma, 10 μL reagent‐ method 2). Lag time ( lag time ); endogenous thrombin potential ( ETP ); peak ( peak ); and time to peak ( ttpeak ) were assessed on the thrombin generation curves.
Results
There was excellent agreement between methods 1 and 2 for all parameters. Lin's concordance coefficients were 0.97, 0.94, 0.96, and 0.96 for lag time, ETP, ttpeak , and peak , respectively. There was a small bias for all parameters ( p < 0.05), resulting in a significant change for lag time only. There was a significant predictive linear equation that, when modeled, allowed the conversion of method 2 to method 1 values. The methods had similar variation when measuring TG variables.
Conclusions
Based on the results in this small group of dogs, we conclude that low‐volume CAT appears to be an alternative to the standard testing method in dogs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
- Department of Small Animal Clinical Sciences, School of Veterinary Medicine, University College Dublin, Dublin, Ireland.
ORCID-Profile: Erin M Phillips, Shauna L Blois
Förderung
- OVC Pet Trust
Zitieren
APA
Phillips, E. M., Blois, S. L., Monteith, G., Abrams-Ogg, A. C. G., Wood, R. D., & Cuq, B. (2026). Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs. Veterinary Clinical Pathology, 55(1), 23-29. https://doi.org/10.1111/vcp.70088
Vancouver
Phillips EM, Blois SL, Monteith G, Abrams-Ogg ACG, Wood RD, Cuq B. Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs. Veterinary Clinical Pathology. 2026;55(1):23-29. doi:10.1111/vcp.70088
BibTeX
@article{Phillips2026,
author = {Phillips, Erin M and Blois, Shauna L and Monteith, Gabrielle and Abrams-Ogg, Anthony C G and Wood, R Darren and Cuq, Benoît},
title = {Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs},
journal = {Veterinary Clinical Pathology},
year = {2026},
volume = {55},
number = {1},
pages = {23--29},
doi = {10.1111/vcp.70088}
}
EUVIMED