EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review

Chinelo P Onyenekwu iD, Debra M Lehman, Brittany Trower, Paula Woywod, Joseph P Connor

Transfusion · 2026-11 · 66 (11) · 2123-2131

DOI: 10.1111/trf.70409 ↗

At a glance

Journal article in Transfusion, published online on 2026-09-26. Written by Chinelo P Onyenekwu and 4 co-authors. Institution: Department of Pathology and Laboratory Medicine, Transfusion Medicine Division, University of Wisconsin-Madison, Madison, Wisconsin, USA. Major MEDLINE topics: Trauma Centers, Blood Transfusion, ABO Blood-Group System, Wounds and Injuries. 37 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Low‐titer O whole blood (LTOWB) has been increasingly incorporated into trauma resuscitation and massive transfusion protocols (MTPs). Recent randomized trials have not demonstrated superiority of prehospital LTOWB over component‐based resuscitation, while the utilization and sustainability of LTOWB programs, particularly in low‐volume trauma systems, remain incompletely characterized. Study Design and Methods This was a 6‐year review (April 2019–April 2025) of trauma MTPs at a level 1 trauma center with a low MTP frequency. Transfusion service logs, trauma flowsheets, prehospital and electronic medical records were reviewed for product usage, LTOWB utilization and discard patterns, and clinical outcomes.

Results

One hundred and twenty‐five MTPs were identified (122 component‐only and 11 LTOWB‐supported), with predominantly male (70%) and 81% blunt trauma. Component MTPs had a median RBC utilization of 6 units; 45% required ≤1 MTP line. Prehospital LTOWB use was limited: 33% of units were transfused, and only 2 of 13 patients requiring an MTP received prehospital LTOWB. LTOWB‐supported MTPs typically issued 10 units, and most patients received 1–2 units. Of 524 LTOWB units procured during the first 6 months, 201 were transfused and 323 discarded (62%), with a peak discard rate of 81% early in rollout. Overall, 30‐day mortality was 54%, and 25% occurred within 4 h.

Conclusions

LTOWB use was limited, and early wastage was substantial. LTOWB implementation in low‐volume centers should align inventory and protocols with clinical demand; stewardship measures may reduce waste and improve sustainability.

Subjects

MeSH terms (MEDLINE)

Trauma CentersBlood TransfusionABO Blood-Group SystemWounds and InjuriesHumansMaleFemaleAdultResuscitationMiddle AgedRetrospective Studies

Author keywords

low‐volume trauma centermassive transfusionprehospital transfusiontransfusion stewardshiptrauma resuscitationwhole blood

Substances

ABO Blood-Group System

Authors and institutions

  • Department of Pathology and Laboratory Medicine, Transfusion Medicine Division, University of Wisconsin-Madison, Madison, Wisconsin, USA.
  • Transfusion Services Laboratory, University of Wisconsin Hospital and Clinics, Madison, Wisconsin, USA.
  • Department of Nursing - Practice Innovation, University of Wisconsin Hospital and Clinics, Madison, Wisconsin, USA.

ORCID profiles: Chinelo P Onyenekwu

Cite

APA

Onyenekwu, C. P., Lehman, D. M., Trower, B., Woywod, P., & Connor, J. P. (2026). Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review. Transfusion, 66(11), 2123-2131. https://doi.org/10.1111/trf.70409

Vancouver

Onyenekwu CP, Lehman DM, Trower B, Woywod P, Connor JP. Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review. Transfusion. 2026;66(11):2123-2131. doi:10.1111/trf.70409

BibTeX
@article{Onyenekwu2026,
  author = {Onyenekwu, Chinelo P and Lehman, Debra M and Trower, Brittany and Woywod, Paula and Connor, Joseph P},
  title = {Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review},
  journal = {Transfusion},
  year = {2026},
  volume = {66},
  number = {11},
  pages = {2123--2131},
  doi = {10.1111/trf.70409}
}
Start for free →