EUVIMEDOpdag EUVIMED
Crossref

Investigation of the preanalytical stability of blood donor samples

Kai Hourfar, Oliver Xia, Lisa Mainzer, Jan Peilstöcker, Andreas Prothmann, Michael Schmidt iD, Uwe Taborski

Transfusion · 2026-07-03

DOI: 10.1111/trf.70308 ↗

At a glance

Journal article in Transfusion, published online on 2026-07-03. Written by Kai Hourfar and 6 co-authors. Institution: Blood Donor Screening, DRK Blutspendedienst Baden-Württemberg-Hessen gGmbH, Frankfurt, Germany. 16 references.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Centralization of blood donor screening and implementation of fully automated testing platforms have increased sample transport distances. Although transport is usually performed under controlled conditions (2–8°C), temperature excursions may occur. This study investigated the impact of such deviations on blood donor screening using a controlled preanalytical approach. Study Design and Methods Whole blood samples (EDTA‐K3, citrate plasma, and serum tubes) were collected from 10 regular plasma donors per temperature condition ( n = 30) and stored at 4, 22, or −10°C. To assess the impact of temperature excursions on analytical sensitivity, samples were supplemented with positive material representing low‐level analytes relevant for blood donor screening, including infectious serology and quantitative parameters. Samples were analyzed for key transfusion‐relevant markers for up to 8 days post‐collection using CE‐certified automated systems from Roche, Beckman Coulter, and Werfen.

Results

Both qualitative (infectious serology, nucleic acid amplification testing, blood group) and quantitative parameters (e.g., immunoglobulin G and total protein) remained stable across all temperatures and time points. Analytical sensitivity and specificity for blood donor screening assays were consistently 100%.

Discussion

High analytical stability was demonstrated across a broad temperature range (−10 to 22°C), simulating extreme transport conditions. Reliable blood donor screening was achievable even after up to 8 days of storage without immediate centrifugation. These findings suggest that moderate temperature excursions during transport may not compromise screening results and that extending acceptable preanalytical conditions could optimize logistics, reduce sample discard, and support continuous availability of safe blood products.

Authors and institutions

  • Blood Donor Screening, DRK Blutspendedienst Baden-Württemberg-Hessen gGmbH, Frankfurt, Germany.
  • Blood Donor Screening, Octapharma Plasma GmbH, Langenfeld, Germany.

ORCID profiles: Michael Schmidt

Cite

APA

Hourfar, K., Xia, O., Mainzer, L., Peilstöcker, J., Prothmann, A., Schmidt, M., & Taborski, U. (2026). Investigation of the preanalytical stability of blood donor samples. Transfusion. https://doi.org/10.1111/trf.70308

Vancouver

Hourfar K, Xia O, Mainzer L, Peilstöcker J, Prothmann A, Schmidt M, et al. Investigation of the preanalytical stability of blood donor samples. Transfusion. 2026. doi:10.1111/trf.70308

BibTeX
@article{Hourfar2026,
  author = {Hourfar, Kai and Xia, Oliver and Mainzer, Lisa and Peilstöcker, Jan and Prothmann, Andreas and Schmidt, Michael and Taborski, Uwe},
  title = {Investigation of the preanalytical stability of blood donor samples},
  journal = {Transfusion},
  year = {2026},
  doi = {10.1111/trf.70308}
}
Start for free →