EUVIMEDOpdag EUVIMED
Open access

Confidential unit exclusion (cue): Impact on transfusion safety

Rita Queirós Pereira iD, Carlos Braga, Miguel Lima Basto, Diana Carneiro-Leão, Sofia Teixeira, Susana Nobre Fernandes, Fernando Araújo

Transfusion · 2026-08 · 66 (8) · 1475-1479

DOI: 10.1111/trf.70271 ↗

At a glance

Journal article in Transfusion, published online on 2026-05-16. Written by Rita Queirós Pereira and 6 co-authors. Institution: Immunohemotherapy Department, São João Local Health Unit, Porto, Portugal. Major MEDLINE topics: Blood Safety, Blood Donors, Blood Transfusion, Transfusion Reaction. 15 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Confidential Unit Exclusion (CUE) was introduced when earlier‐generation assays had lower sensitivity and longer infectious window periods for transfusion‐transmitted infections. Improvements in serological and molecular testing have raised questions about its contemporary utility. This study evaluated the use and predictive performance of CUE at São João Local Health Unit Blood Bank, Porto – Portugal.

Methods

A retrospective descriptive study assessed all donations with CUE between January 1, 1999 and August 5, 2025. Donor demographics, CUE outcomes, and laboratory results were retrieved. Confirmed reactive serological and nucleic acid testing (NAT) findings were reviewed. The main analytical focus was on findings suggestive of possible window‐period infection after a CUE‐excluded donation. Sensitivity, specificity, and positive predictive value (PPV) were calculated; associations between CUE status and reactivity were assessed with Fisher's exact test and odds ratios (OR) with 95% confidence intervals.

Results

Among 533,227 donations, 2289 (0.429%) underwent CUE self‐exclusion. Twenty‐four (1.05%) showed initially reactive markers at the time of the CUE‐excluded donation or during follow‐up, but none were confirmed as findings suggestive of window‐period infections. CUE demonstrated a sensitivity of 0%, specificity of 0.7%, and PPV of 0%. In the 2009–2025 cohort ( n = 344,666), no reactive results occurred in the CUE group, whereas 149 (0.043%) occurred in the non‐CUE group. No significant association was found between CUE and reactivity ( p = 0.388; OR = 2.045; 95% CI 0.286–14.627).

Discussion

In this retrospective single‐center cohort, CUE showed no measurable diagnostic or predictive value beyond routine screening and identifying possible window‐period infections.

Subjects

MeSH terms (MEDLINE)

Blood SafetyBlood DonorsBlood TransfusionTransfusion ReactionDonor SelectionHumansRetrospective StudiesBlood DonationFemalePortugalMaleBlood Banks

Author keywords

blood banksblood donorsblood safetydonor exclusiontransfusion‐transmitted infection

Authors and institutions

  • Immunohemotherapy Department, São João Local Health Unit, Porto, Portugal.
  • Department of Community Medicine, Health Information and Decision, University of Porto Faculty of Medicine, Porto, Portugal.

ORCID profiles: Rita Queirós Pereira

Cite

APA

Queirós Pereira, R., Braga, C., Lima Basto, M., Carneiro-Leão, D., Teixeira, S., Nobre Fernandes, S., & Araújo, F. (2026). Confidential unit exclusion (cue): Impact on transfusion safety. Transfusion, 66(8), 1475-1479. https://doi.org/10.1111/trf.70271

Vancouver

Queirós Pereira R, Braga C, Lima Basto M, Carneiro-Leão D, Teixeira S, Nobre Fernandes S, et al. Confidential unit exclusion (cue): Impact on transfusion safety. Transfusion. 2026;66(8):1475-1479. doi:10.1111/trf.70271

BibTeX
@article{QueirsPereira2026,
  author = {Queirós Pereira, Rita and Braga, Carlos and Lima Basto, Miguel and Carneiro-Leão, Diana and Teixeira, Sofia and Nobre Fernandes, Susana and Araújo, Fernando},
  title = {Confidential unit exclusion (cue): Impact on transfusion safety},
  journal = {Transfusion},
  year = {2026},
  volume = {66},
  number = {8},
  pages = {1475--1479},
  doi = {10.1111/trf.70271}
}
Start for free →