Evaluationsstudie in der Zeitschrift Transfusion, 2025. Verfasst von Yigit Baykara und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Stanford University School of Medicine, Stanford, California, USA. Hauptthemen laut MEDLINE: Plasma, Transportation. Die Arbeit nennt 9 Literaturangaben.
Abstract (Originalsprache)
Background
Thawed fresh frozen plasma (FFP) is subject to coagulation factor degradation, particularly factors V and VIII, prompting strict storage guidelines of 1–6°C post‐thaw. However, real‐world clinical practice often involves temporary deviations from ideal conditions, especially during transport. This study evaluated whether thawed FFP stored in standard transport coolers maintains coagulation factor integrity. Study Design and Methods Fourteen FFP units were thawed at 30–37°C and divided into two groups: control units stored immediately at 4°C and experimental units exposed to simulated transport conditions in validated coolers for up to 6 h post‐thaw. Samples were obtained at 0, 3, and 6 h for temperature measurement and coagulation testing, including factor V and VIII activity and prothrombin time (PT). A one‐tailed t ‐test was used for statistical comparisons.
Results
While cooler‐stored units exhibited higher temperatures at 3 and 6 h ( p < .001), no significant differences were observed in factor V or factor VIII activity or PT between experimental and control groups at any time point. Delta analysis confirmed the stability of coagulation parameters over time.
Conclusion
Short‐term storage of thawed FFP in validated transport coolers does not compromise coagulation factor activity or PT. These findings support the return of thawed plasma units to inventory when stored in transport coolers for up to 6 h, reducing unnecessary product waste without compromising product safety and efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology, Stanford University School of Medicine, Stanford, California, USA.
- Transfusion Medicine Service, Stanford Health Care, Stanford, California, USA.
- Department of Special Coagulation, Clinical Laboratories, Stanford Health Care, Stanford, California, USA.
ORCID-Profile: Yigit Baykara, Jing Jin
Zitieren
APA
Baykara, Y., Poblacion, J., Jin, J., & Virk, M. (2025). Validating transport conditions of fresh frozen plasma units. Transfusion. https://doi.org/10.1111/trf.18435
Vancouver
Baykara Y, Poblacion J, Jin J, Virk M. Validating transport conditions of fresh frozen plasma units. Transfusion. 2025. doi:10.1111/trf.18435
BibTeX
@article{Baykara2025,
author = {Baykara, Yigit and Poblacion, Jesierose and Jin, Jing and Virk, Mrigender},
title = {Validating transport conditions of fresh frozen plasma units},
journal = {Transfusion},
year = {2025},
doi = {10.1111/trf.18435}
}
EUVIMED