EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of pathogen reduced plasmas from maxi‐pools combined with fast thawing

Marja-Kaisa Auvinen iD, Folke Knutson, Helena Löf

Transfusion Medicine · 2024

DOI: 10.1111/tme.13106 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Transfusion Medicine, 2024. Verfasst von Marja-Kaisa Auvinen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Immunology and Transfusion Medicine, Uppsala University Hospital Blood Transfusion Center, Uppsala, Sweden. Hauptthemen laut MEDLINE: Plasma, Furocoumarins, Blood Preservation. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cerus Europe B.V..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Fast thawing for emergency situations and reduction of plasma wastage.

Background

Evaluation of plasma units, pooled and pathogen reduced (PR) in “maxi‐pools” with amotosalen and UVA light, and fast thawing. Methods/Materials Per replicate, 10 WB‐derived leukocyte depleted plasma units were frozen within 24 h at ≤ −25°C and stored for 7 days. After thawing, a maxi‐pool was constituted from the 10 units. After splitting into 4 sub‐pools of 650 mL, the sub‐pools were PR treated then split into 3 units resulting in 12 PR plasma units at 200 mL. Hundred and twenty PR plasma units were produced in total. The units were frozen at ≤ −25°C for 1 week, then thawed either in a fast plasma thawer for 5 min or in other control devices (17 to 23 min). FVIII:C, Fibrinogen, albumin, IgG, protein S and VWF were measured in plasma units, maxi‐pools and plasmas after PR treatment and thawing.

Results

There was a statistically significant ( p < 0.001) but still clinically acceptable (over the recommended levels of ≥0.5 IU/mL and ≥2 g/L) reduction of FVIII:C and Fibrinogen after PR with 69% and 87% recovery, respectively. Other proteins were not significantly affected by the processes.

Conclusion

Pooling 10 plasma units before the PR treatment standardises volume and protein content of plasma units. Besides the economic value of generating 12 products for transfusion, this procedure combined with a thawing time of about 5 min is of value in emergency situations and may reduce plasma wastage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlasmaFurocoumarinsBlood PreservationHumansCryopreservationUltraviolet RaysFemaleMaleBlood SafetyFreezingTime Factors

Stichwörter der Autor:innen

fast thawingmaxi‐poolspathogen reducedplasma

Substanzen

Furocoumarinsamotosalen

Autor:innen und Institutionen

  • Department of Clinical Immunology and Transfusion Medicine, Uppsala University Hospital Blood Transfusion Center, Uppsala, Sweden.

ORCID-Profile: Marja-Kaisa Auvinen

Förderung

  • Cerus Europe B.V.

Zitieren

APA

Auvinen, M. K., Knutson, F., & Löf, H. (2024). Validation of pathogen reduced plasmas from maxi‐pools combined with fast thawing. Transfusion Medicine. https://doi.org/10.1111/tme.13106

Vancouver

Auvinen MK, Knutson F, Löf H. Validation of pathogen reduced plasmas from maxi‐pools combined with fast thawing. Transfusion Medicine. 2024. doi:10.1111/tme.13106

BibTeX
@article{Auvinen2024,
  author = {Auvinen, Marja-Kaisa and Knutson, Folke and Löf, Helena},
  title = {Validation of pathogen reduced plasmas from maxi‐pools combined with fast thawing},
  journal = {Transfusion Medicine},
  year = {2024},
  doi = {10.1111/tme.13106}
}
Kostenlos starten →