EUVIMEDEUVIMED entdecken
Crossref

Stability of immunohaematological reagents used for blood typing of recipients in the tube technique

Julia Hermes, Mariane Stefanes Carloto, Amanda Leal, Flávia Martinello

Transfusion Medicine · 2024

DOI: 10.1111/tme.13076 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion Medicine, 2024. Verfasst von Julia Hermes und 3 weiteren Autor:innen. Beteiligte Einrichtung: Health Sciences Center, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil. Hauptthemen laut MEDLINE: Blood Grouping and Crossmatching, ABO Blood-Group System. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives The storage temperature of immunohaematological reagents generally ranges from 2 to 8°C, and they should be utilised at room temperature. This study aimed to analyse the stability of immunohaematological reagents used in ABO and RhD typing.

Methods

The evaluation encompassed the potency, specificity, and integrity of anti‐A, anti‐B, anti‐D, RhD control sera, and A 1 and B red blood cells (RBC) reagents after long (8 h) and short (4 h) daily periods of exposure to room temperature (20–24°C), 5 days a week for 4 weeks. Additionally, the A 1 and B RBC reagents were exposed daily for 11 h and 30 min at room temperature, including 30 more minutes at room temperature with simultaneous homogenisation through equipment. For the control, an aliquot of each reagent was constantly stored at refrigeration temperature, while another was exposed to room temperature for 12 h daily. Tests conducted included reaction intensity, titration, and avidity for antisera, reaction intensity, free haemoglobin determination, and electrical conductivity for the RBC reagents.

Results

The antisera maintained the reaction intensity. The titre and avidity of the antisera satisfied the minimum Brazilian requirements after different exposure periods. A higher free haemoglobin concentration was noted in the RBC reagents subjected to room temperature and simultaneous homogenisation, although this did not affect the potency and specificity. The electrical conductivity average of the RBC reagent remained consistent.

Conclusion

The findings indicate that the immunohaematological reagents from a specific manufacturer are stable under the tested temperature, ensuring the quality of the results under these conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Grouping and CrossmatchingABO Blood-Group SystemHumansIndicators and ReagentsRh-Hr Blood-Group SystemTemperatureErythrocytes

Stichwörter der Autor:innen

ABO and RhD phenotypingimmunohaematological reagentsquality controlstability

Substanzen

ABO Blood-Group SystemIndicators and ReagentsRh-Hr Blood-Group System

Autor:innen und Institutionen

  • Health Sciences Center, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil.
  • Santa Catarina Hematology and Hemotherapy Center, Florianópolis, Santa Catarina, Brazil.

Zitieren

APA

Hermes, J., Carloto, M. S., Leal, A., & Martinello, F. (2024). Stability of immunohaematological reagents used for blood typing of recipients in the tube technique. Transfusion Medicine. https://doi.org/10.1111/tme.13076

Vancouver

Hermes J, Carloto MS, Leal A, Martinello F. Stability of immunohaematological reagents used for blood typing of recipients in the tube technique. Transfusion Medicine. 2024. doi:10.1111/tme.13076

BibTeX
@article{Hermes2024,
  author = {Hermes, Julia and Carloto, Mariane Stefanes and Leal, Amanda and Martinello, Flávia},
  title = {Stability of immunohaematological reagents used for blood typing of recipients in the tube technique},
  journal = {Transfusion Medicine},
  year = {2024},
  doi = {10.1111/tme.13076}
}
Kostenlos starten →