EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility

Alexis Janin, Cédric Usureau, Marie‐Joëlle Apithy, Nicolas Congy‐Jolivet, Barbara Proust, Camille Humeau, Isabelle Jollet, Grégory Gatouillat, Jean‐Luc Taupin, Véronique Letort

HLA · 2026-11 · 108 (5)

DOI: 10.1111/tan.71098 ↗

At a glance

Journal article in HLA, published online on 2026-11-23. Written by Alexis Janin and 9 co-authors. 11 references. The full text is freely available (open access, CC BY 4.0). Funded by: Agence Nationale de la Recherche.

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

The Luminex Single Antigen (LSA) bead assay is the reference method for anti‐HLA antibody detection in transplantation. Mean Fluorescence Intensity (MFI) is a semi‐quantitative measure of antibody strength but saturates at high values. Serum dilution, recommended to refine quantification, has a non‐linear and poorly characterised relationship to neat MFI. We retrospectively analysed paired neat and 1:10 diluted MFI from two cohorts: a monocentric development cohort (Saint‐Louis Hospital, AP‐HP) used for model fitting, and a multicentric external validation cohort from five histocompatibility laboratories used to assess transportability. The dilution function was modelled by locally weighted scatterplot smoothing (LOWESS) regression, with hyperparameters selected by the Bayesian Information Criterion (BIC); 95% prediction intervals were estimated locally from candidate residual distributions (Gaussian and SkewNormal). The empirical low‐MFI slope was compared to the theoretical 0.10 expected from a 1:10 dilution. The development dataset comprised 237,547 paired measurements from 644 patients and 1,965 sera. The retained model was a degree‐2 locally quadratic estimator with Gaussian kernel and bandwidth 1500; residuals were best fitted by a SkewNormal distribution. For a neat MFI of 8,000, the predicted diluted MFI was 2,130 (95% PI: 650–4,640). The empirical low‐MFI slope was 0.219, substantially exceeding the theoretical 0.10. External validation on 18,642 measurements from 104 sera across four laboratories yielded a 95% prediction interval coverage of 93.9%. A non‐parametric model with locally adapted prediction intervals is provided to predict the 1:10 diluted MFI without performing serum dilution, supporting clinical decision‐making. Each predicted value comes with its prediction interval, whose width increases with neat MFI and is greatest in the saturating range.

Funding

  • Agence Nationale de la Recherche

Cite

APA

Janin, A., Usureau, C., Apithy, M., Congy‐Jolivet, N., Proust, B., Humeau, C., Jollet, I., Gatouillat, G., Taupin, J., & Letort, V. (2026). Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility. HLA, 108(5). https://doi.org/10.1111/tan.71098

Vancouver

Janin A, Usureau C, Apithy M, Congy‐Jolivet N, Proust B, Humeau C, et al. Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility. HLA. 2026;108(5). doi:10.1111/tan.71098

BibTeX
@article{Janin2026,
  author = {Janin, Alexis and Usureau, Cédric and Apithy, Marie‐Joëlle and Congy‐Jolivet, Nicolas and Proust, Barbara and Humeau, Camille and Jollet, Isabelle and Gatouillat, Grégory and Taupin, Jean‐Luc and Letort, Véronique},
  title = {Predicting the 1:10 Diluted MFI of Luminex Single Antigen Beads: A Tool for Assessing Antibody Strength and Desensitisation Eligibility},
  journal = {HLA},
  year = {2026},
  volume = {108},
  number = {5},
  doi = {10.1111/tan.71098}
}
Start for free →