EUVIMEDOpdag EUVIMED
Open access

A Flow Cytometry Crossmatch With Combined Cytotoxicity and IgG Detection: Ten Years of Use in Deceased Donor Kidney Allocation

Mats Alheim iD, Torsten Eich

HLA · 2026

DOI: 10.1111/tan.70800 ↗

At a glance

Journal article in HLA, 2026. Written by Mats Alheim and 1 co-authors. Institution: Department of Laboratory Medicine, Division of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, Stockholm, Sweden. Major MEDLINE topics: Flow Cytometry, Kidney Transplantation, Immunoglobulin G, Histocompatibility Testing. 29 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Virtual crossmatch (VXM) is increasingly used in deceased‐donor kidney allocation, raising questions about the added value of a physical crossmatch (PXM) when donor‐specific antibody (DSA) are absent. We applied our previously described flow cytometry–based assay (FCtox), combining complement‐mediated cytotoxicity and IgG binding, across 3236 routine crossmatches performed between 2018 and 2024. All donor offers underwent VXM followed by prospective PXM. Among 704 patients, 95% of FCtox assays were performed in VXM‐ cases. FCtox positivity was uncommon in VXM‐ cases (9%), and overall concordance between VXM and FCtox was high (89%). Further analyses indicated that isolated FCtox abnormalities in VXM‐ cases primarily reflect patient‐specific background reactivity, including non‐HLA or IgM‐mediated effects. Among transplanted VXM‐ patients with FCtox positivity ( n = 12), no early antibody‐mediated rejection occurred. In VXM+ patients, DSA mean fluorescence intensity (MFI) values above 5000 were associated with increased likelihood of FCtox IgG positivity, although overlap between groups limited the ability of MFI alone to predict FCtox IgG reactivity. Overall, VXM reliably identified clinically meaningful immunologic risk, while FCtox added little value in VXM‐ candidates but remained useful in selected VXM+ or discordant scenarios. These findings support a VXM‐driven allocation strategy with selective rather than routine use of PXM.

Subjects

MeSH terms (MEDLINE)

Flow CytometryKidney TransplantationImmunoglobulin GHistocompatibility TestingIsoantibodiesGraft RejectionHumansFemaleMaleTissue DonorsMiddle AgedHLA AntigensAdult

Author keywords

HLA antibodiesdonor‐specific antibodiesflow cytometry crossmatchkidney transplantationvirtual crossmatch

Substances

Immunoglobulin GIsoantibodiesHLA Antigens

Authors and institutions

  • Department of Laboratory Medicine, Division of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, Stockholm, Sweden.

ORCID profiles: Mats Alheim

Cite

APA

Alheim, M., & Eich, T. (2026). A Flow Cytometry Crossmatch With Combined Cytotoxicity and IgG Detection: Ten Years of Use in Deceased Donor Kidney Allocation. HLA. https://doi.org/10.1111/tan.70800

Vancouver

Alheim M, Eich T. A Flow Cytometry Crossmatch With Combined Cytotoxicity and IgG Detection: Ten Years of Use in Deceased Donor Kidney Allocation. HLA. 2026. doi:10.1111/tan.70800

BibTeX
@article{Alheim2026,
  author = {Alheim, Mats and Eich, Torsten},
  title = {A Flow Cytometry Crossmatch With Combined Cytotoxicity and IgG Detection: Ten Years of Use in Deceased Donor Kidney Allocation},
  journal = {HLA},
  year = {2026},
  doi = {10.1111/tan.70800}
}