Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study
Skin Research and Technology · 2026
DOI: 10.1111/srt.70393 ↗At a glance
Randomisierte kontrollierte Studie in Skin Research and Technology, 2026. Written by Kwang Ho Yoo and 2 co-authors. Institution: Department of Dermatology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, Gyeonggi-do, Republic…. Major MEDLINE topics: Eyebrows, Ultrasonic Therapy, Rhytidoplasty, Skin Aging. 14 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Eunsung Global Co., Ltd..
Abstract (original language)
Background
High‐intensity focused ultrasound (HIFU) is widely used for noninvasive eyebrow lifting, but within‐subject comparisons of cartridge focal depths are scarce.
Objective
To evaluate the efficacy and safety of 1.5‐ and 3.0‐mm cartridges for eyebrow lifting in Korean adults, with an exploratory between‐depth comparison.
Methods
In this randomized split‐face study, 20 Korean adults were treated once with the 1.5‐mm cartridge on one side and the 3.0‐mm contralaterally (225 J/side). Average and maximum eyebrow heights (AEH, primary; MEH, secondary) were measured from standardized photographs at baseline, post‐treatment, and weeks 1, 4, and 12. Satisfaction, pain, and adverse events were recorded.
Results
Both measures increased significantly at all time points (unadjusted p < 0.05). At week 12, AEH increased by 1.76 ± 1.19 mm (1.5‐mm) and 1.23 ± 1.33 mm (3.0‐mm); 98.75% one‐sided CI lower bounds (1.10 and 0.51 mm) met the corrected primary efficacy criterion. MEH met the separately corrected criterion with the 1.5‐mm (0.57 mm) but not the 3.0‐mm cartridge (−0.08 mm). The exploratory week‐12 AEH difference was nonsignificant ( p = 0.116). No treatment‐related adverse events occurred over 12 weeks, supporting short‐term tolerability in this cohort rather than definitive safety.
Conclusions
Each cartridge was associated with significant within‐subject increases in photographic eyebrow‐height measures through 12 weeks and high satisfaction, although the corrected MEH criterion was not met with the 3.0‐mm cartridge. Without a sham control, findings indicate within‐subject improvement, not causal efficacy; the between‐cartridge comparison is inconclusive, not evidence of equivalence. Larger, sham‐controlled studies are needed.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Dermatology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, Gyeonggi-do, Republic of Korea.
- Clinical & Academic Affairs, Eunsung Global Co., Ltd., Wonju, Republic of Korea.
ORCID profiles: Kwang Ho Yoo
Funding
- Eunsung Global Co., Ltd.
Cite
APA
Yoo, K. H., Song, H., & Choi, Y. (2026). Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study. Skin Research and Technology. https://doi.org/10.1111/srt.70393
Vancouver
Yoo KH, Song H, Choi Y. Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study. Skin Research and Technology. 2026. doi:10.1111/srt.70393
BibTeX
@article{Yoo2026,
author = {Yoo, Kwang Ho and Song, Hyewon and Choi, Yuhwa},
title = {Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study},
journal = {Skin Research and Technology},
year = {2026},
doi = {10.1111/srt.70393}
}
EUVIMED