EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC-ND 4.0

Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study

Kwang Ho Yoo iD, Hyewon Song, Yuhwa Choi

Skin Research and Technology · 2026

DOI: 10.1111/srt.70393 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Skin Research and Technology, 2026. Verfasst von Kwang Ho Yoo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, Gyeonggi-do, Republic…. Hauptthemen laut MEDLINE: Eyebrows, Ultrasonic Therapy, Rhytidoplasty, Skin Aging. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Eunsung Global Co., Ltd..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High‐intensity focused ultrasound (HIFU) is widely used for noninvasive eyebrow lifting, but within‐subject comparisons of cartridge focal depths are scarce.

Objective

To evaluate the efficacy and safety of 1.5‐ and 3.0‐mm cartridges for eyebrow lifting in Korean adults, with an exploratory between‐depth comparison.

Methods

In this randomized split‐face study, 20 Korean adults were treated once with the 1.5‐mm cartridge on one side and the 3.0‐mm contralaterally (225 J/side). Average and maximum eyebrow heights (AEH, primary; MEH, secondary) were measured from standardized photographs at baseline, post‐treatment, and weeks 1, 4, and 12. Satisfaction, pain, and adverse events were recorded.

Results

Both measures increased significantly at all time points (unadjusted p < 0.05). At week 12, AEH increased by 1.76 ± 1.19 mm (1.5‐mm) and 1.23 ± 1.33 mm (3.0‐mm); 98.75% one‐sided CI lower bounds (1.10 and 0.51 mm) met the corrected primary efficacy criterion. MEH met the separately corrected criterion with the 1.5‐mm (0.57 mm) but not the 3.0‐mm cartridge (−0.08 mm). The exploratory week‐12 AEH difference was nonsignificant ( p = 0.116). No treatment‐related adverse events occurred over 12 weeks, supporting short‐term tolerability in this cohort rather than definitive safety.

Conclusions

Each cartridge was associated with significant within‐subject increases in photographic eyebrow‐height measures through 12 weeks and high satisfaction, although the corrected MEH criterion was not met with the 3.0‐mm cartridge. Without a sham control, findings indicate within‐subject improvement, not causal efficacy; the between‐cartridge comparison is inconclusive, not evidence of equivalence. Larger, sham‐controlled studies are needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EyebrowsUltrasonic TherapyRhytidoplastySkin AgingHumansFemaleAdultMaleRepublic of KoreaMiddle AgedProspective StudiesTreatment OutcomePatient Satisfaction

Stichwörter der Autor:innen

Koreaneyebrow liftingfocal depthhigh‐intensity focused ultrasoundskin tightening

Autor:innen und Institutionen

  • Department of Dermatology, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, Gyeonggi-do, Republic of Korea.
  • Clinical & Academic Affairs, Eunsung Global Co., Ltd., Wonju, Republic of Korea.

ORCID-Profile: Kwang Ho Yoo

Förderung

  • Eunsung Global Co., Ltd.

Zitieren

APA

Yoo, K. H., Song, H., & Choi, Y. (2026). Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study. Skin Research and Technology. https://doi.org/10.1111/srt.70393

Vancouver

Yoo KH, Song H, Choi Y. Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study. Skin Research and Technology. 2026. doi:10.1111/srt.70393

BibTeX
@article{Yoo2026,
  author = {Yoo, Kwang Ho and Song, Hyewon and Choi, Yuhwa},
  title = {Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study},
  journal = {Skin Research and Technology},
  year = {2026},
  doi = {10.1111/srt.70393}
}
Kostenlos starten →