Histological damage characteristics and quantitive analysis of porcine skin with non‐insulated microneedle radiofrequency
Skin Research and Technology · 2023
DOI: 10.1111/srt.13396 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skin Research and Technology, 2023. Verfasst von Jiayi Feng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laser Aesthetic Center, Plastic Surgery Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China. Hauptthemen laut MEDLINE: Cosmetic Techniques, Skin Aging. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Special Research Fund for Plastic Surgery Hospital, the Chinese Academy of Medical Sciences, and Peking Union Medical College.
Abstract (Originalsprache)
Objective
In recent years, the microneedle radiofrequency (MRF) has been widely used for skin rejuvenation, but histological studies on the immediate trauma caused by different parameters of non‐insulated RF microneedles Methods The skin of three pigs was treated with different needle depths, pulse widths and energy levels of non‐insulated microneedle RF. Samples were collected before, immediately, and 2 weeks after treatment. The immediate histological response of each group was assessed and quantified by hematoxylin and eosin staining, Masson staining and Victoria Blue staining.
Results
In the treatment of non‐insulated microneedle RF, different energy levels affected mainly the range of thermal damage ( p = 0.044), and different needle depths affected mainly the depth of the cavity ( p = 0.022). But the width of the coagulation zone width was determined by different factors. There was no significant difference in the histology of immediate damage caused by different pulse widths. Reepithelialization of the epidermis and basic wound repair can be completed within 2 weeks.
Conclusion
Non‐insulated RF microneedle therapy is an effective and safe treatment that can stimulate dermal wound healing with less thermal coagulation and a wide range of reversible thermal damage. However, it should be noted that the set needle depth may not correspond to the actual penetration depth, nor to the actual depth of histologic trauma.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laser Aesthetic Center, Plastic Surgery Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing, China.
ORCID-Profile: Jiayi Feng
Förderung
- Special Research Fund for Plastic Surgery Hospital, the Chinese Academy of Medical Sciences, and Peking Union Medical College
Zitieren
APA
Feng, J., Zhang, L., Qi, J., & Huang, L. (2023). Histological damage characteristics and quantitive analysis of porcine skin with non‐insulated microneedle radiofrequency. Skin Research and Technology. https://doi.org/10.1111/srt.13396
Vancouver
Feng J, Zhang L, Qi J, Huang L. Histological damage characteristics and quantitive analysis of porcine skin with non‐insulated microneedle radiofrequency. Skin Research and Technology. 2023. doi:10.1111/srt.13396
BibTeX
@article{Feng2023,
author = {Feng, Jiayi and Zhang, Ling and Qi, Jun and Huang, Lvping},
title = {Histological damage characteristics and quantitive analysis of porcine skin with non‐insulated microneedle radiofrequency},
journal = {Skin Research and Technology},
year = {2023},
doi = {10.1111/srt.13396}
}
EUVIMED