Track and Treadmill Lactate Assessments Are Not Interchangeable for Training Prescription in Elite Distance Runners
Scandinavian Journal of Medicine & Science in Sports · 2026-04 · 36 (4)
DOI: 10.1111/sms.70286 ↗At a glance
Journal article in Scandinavian Journal of Medicine & Science in Sports, published online on 2026-04-14. Written by Yasuhiro Suzuki and 4 co-authors. Institution: Center for General Education, Tokyo Keizai University, Tokyo, Japan. Major MEDLINE topics: Exercise Test, Lactic Acid, Running. 29 references. Funded by: Japan Society for the Promotion of Science (JSPS).
Abstract (original language)
This study characterized physiological and biomechanical differences between track and treadmill running in elite distance runners at race‐relevant intensities. Nine male Tier 4 runners (5000 m personal best: 13:35 ± 0:03 min:s; 10 000 m: 27:44 ± 0:06 min:s) completed six‐stage incremental tests (286–375 m·min −1 ) on both a 300‐m track and a motorized treadmill (0% grade) in a randomized crossover design. Blood lactate concentration was significantly higher during track running across all stages ( p < 0.001, η 2 p = 0.784), with the difference increasing progressively from 1.0 mmol·L −1 at stage 1 to 3.7 mmol·L −1 at stage 6 (condition × stage interaction: p < 0.001, η 2 p = 0.624). Running velocities at fixed blood lactate concentrations were lower during track running at both 4 mmol·L −1 (329.6 ± 4.3 vs. 345.1 ± 4.1 m·min −1 ; p = 0.008) and 6 mmol·L −1 (344.2 ± 3.1 vs. 359.4 ± 3.8 m·min −1 ; p = 0.012), corresponding to velocity adjustments of approximately 7–8 s·km −1 . Ground contact times were significantly longer during track running at high intensities. In eight runners with 10 000 m season bests, track‐based velocity at 6 mmol·L −1 demonstrated superior predictive validity ( r = −0.973, R 2 = 0.948, p < 0.001) compared to treadmill assessment ( r = −0.695, R 2 = 0.483, p = 0.061). Track and treadmill lactate assessments are not interchangeable for training prescription; track‐based assessment should be prioritized when feasible. At threshold speeds typical of this cohort (~21 km·h −1 ), treadmill‐derived threshold velocities exceeded track‐derived values by approximately 7–8 s·km −1 . Practitioners should apply this correction in both directions: when transferring treadmill‐derived zones to track training, prescribed track velocities should be reduced by this margin; conversely, to replicate equivalent track intensity on a treadmill, treadmill speed should be raised by the same amount. The required correction is speed‐dependent and increases at higher running velocities.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Center for General Education, Tokyo Keizai University, Tokyo, Japan.
- Research Institute of Physical Fitness, Japan Women's College of Physical Education, Tokyo, Japan.
- Graduate School of Arts and Sciences, The University of Tokyo, Tokyo, Japan.
- School of Physical Education, Department of Competitive Sports, Tokai University, Kanagawa, Japan.
- Faculty of Human Health, Kurume University, Fukuoka, Japan.
ORCID profiles: Naoya Takei
Funding
- Japan Society for the Promotion of Science (JSPS)
Cite
APA
Suzuki, Y., Takei, N., Tanji, F., Yamanaka, R., & Saeki, T. (2026). Track and Treadmill Lactate Assessments Are Not Interchangeable for Training Prescription in Elite Distance Runners. Scandinavian Journal of Medicine & Science in Sports, 36(4). https://doi.org/10.1111/sms.70286
Vancouver
Suzuki Y, Takei N, Tanji F, Yamanaka R, Saeki T. Track and Treadmill Lactate Assessments Are Not Interchangeable for Training Prescription in Elite Distance Runners. Scandinavian Journal of Medicine & Science in Sports. 2026;36(4). doi:10.1111/sms.70286
BibTeX
@article{Suzuki2026,
author = {Suzuki, Yasuhiro and Takei, Naoya and Tanji, Fumiya and Yamanaka, Ryo and Saeki, Tetsuro},
title = {Track and Treadmill Lactate Assessments Are Not Interchangeable for Training Prescription in Elite Distance Runners},
journal = {Scandinavian Journal of Medicine & Science in Sports},
year = {2026},
volume = {36},
number = {4},
doi = {10.1111/sms.70286}
}
EUVIMED