EUVIMEDOpdag EUVIMED
Multizentrische Studie

The Assessment of Subglottic and Cervical Tracheal Stenosis Using a Novel Point‐of‐Care Ultrasound Method: Measurement of Tracheal Radius Curvature

Jieru Lin, Zhina Wang, Mingming Deng, Lin Su, Hong Chen iD, Hanliang Jiang, Yang Xia iD, Xianwei Ye, Nan Zhang, Hongmei Yao, Min Liu iD, Jiaojiao Ma and 5 more

Respirology · 2025

DOI: 10.1111/resp.70081 ↗

At a glance

Multizentrische Studie in Respirology, 2025. Written by Jieru Lin and 16 co-authors. Institution: Department of Respiratory and Critical Care Medicine, Guizhou Provincial People's Hospital, Guiyang, Guizhou Province, China. Major MEDLINE topics: Tracheal Stenosis, Trachea, Point-of-Care Systems, Laryngostenosis. Cited 1 times so far (Crossref); 40 references. Funded by: CAMS Innovation Fund for Medical Sciences, the Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences, National High Level Hospital Clinical Research.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and Objective The air way dimensions are important in the assessment, treatment and follow‐up of patients with tracheal and subglottic stenosis (SGS). Non‐invasive, non‐radioactive methods to assess the degree of stenosis are needed. Point‐of‐care ultrasonography (POCUS) is an effective method for assessing the subglottic diameter and evaluating the abnormal airway. We explore the accuracy of POCUS measurement of the diameter of the subglottic and cervical trachea in patients with SGS and tracheal stenosis.

Methods

In this prospective, multi‐centre study, volunteers and patients with SGS underwent POCUS, CT scanning, and flexible bronchoscopy. A radiologist measured the anteroposterior and transverse diameters of the trachea on the CT images and calculated the mean diameter (CT‐mean). Air column width (ACW) and anterior tracheal wall thickness (ATWT) were obtained by POCUS. The diameter of the subglottic and cervical trachea was calculated using an equation based on the radius of curvature (CR).

Results

A total of 123 volunteers without tracheal disease and 103 patients with SGS participated in this study. We identified strong correlation between airway diameter measurement using US‐CR and CT‐mean ( r = 0.96 and 0.95, p < 0.001, respectively) in both, the control group and in patients with SGS. The diameter of subglottic and cervical trachea assessed by US‐CR is more accurate than the direct measurement of US‐ACW. The intraobserver and interobserver repeatability of US‐CR was excellent (all correlation coefficients > 0.95; p < 0.05).

Conclusion

The airway dimension measured using POCUS based on the radius of the curvature is a reliable tool for assessing the subglottic and cervical tracheal diameters. image

Subjects

MeSH terms (MEDLINE)

Tracheal StenosisTracheaPoint-of-Care SystemsLaryngostenosisHumansFemaleProspective StudiesMiddle AgedMaleUltrasonographyAdultAgedBronchoscopyTomography, X-Ray Computed

Author keywords

cervical tracheal stenosiscurvature radiuspoint‐of‐care ultrasonographysubglottic stenosis

Authors and institutions

  • Department of Respiratory and Critical Care Medicine, Guizhou Provincial People's Hospital, Guiyang, Guizhou Province, China.
  • NHC Key Laboratory of Pulmonary Immunological Disease, Guizhou Provincial People's Hospital, Guiyang, Guizhou Province, China.
  • Department of Pulmonary and Critical Care Medicine ll, Emergency General Hospital, Beijing, China.
  • National Center for Respiratory Medicine, State Key Laboratory of Respiratory Health and Multimorbidity, National Clinical Research Center for Respiratory Diseases, Institute of Respiratory Medicine, Chinese Academy of…
  • Department of Respiratory and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, Shanxi, China.
  • Department of Respiratory and Critical Care Medicine, Second Affiliated Hospital of Harbin Medical University, Harbin, China.

ORCID profiles: Hong Chen, Yang Xia, Min Liu, Gang Hou

Funding

  • CAMS Innovation Fund for Medical Sciences
  • the Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences
  • National High Level Hospital Clinical Research

Cite

APA

Lin, J., Wang, Z., Deng, M., Su, L., Chen, H., Jiang, H., Xia, Y., Ye, X., Zhang, N., Yao, H., Liu, M., Ma, J., Wu, J., Li, X., Zhao, S., Liao, L., & Hou, G. (2025). The Assessment of Subglottic and Cervical Tracheal Stenosis Using a Novel Point‐of‐Care Ultrasound Method: Measurement of Tracheal Radius Curvature. Respirology. https://doi.org/10.1111/resp.70081

Vancouver

Lin J, Wang Z, Deng M, Su L, Chen H, Jiang H, et al. The Assessment of Subglottic and Cervical Tracheal Stenosis Using a Novel Point‐of‐Care Ultrasound Method: Measurement of Tracheal Radius Curvature. Respirology. 2025. doi:10.1111/resp.70081

BibTeX
@article{Lin2025,
  author = {Lin, Jieru and Wang, Zhina and Deng, Mingming and Su, Lin and Chen, Hong and Jiang, Hanliang and Xia, Yang and Ye, Xianwei and Zhang, Nan and Yao, Hongmei and Liu, Min and Ma, Jiaojiao and Wu, Jie and Li, Xuelian and Zhao, Shuai and Liao, Liwei and Hou, Gang},
  title = {The Assessment of Subglottic and Cervical Tracheal Stenosis Using a Novel Point‐of‐Care Ultrasound Method: Measurement of Tracheal Radius Curvature},
  journal = {Respirology},
  year = {2025},
  doi = {10.1111/resp.70081}
}