Safety and efficacy of a novel transbronchial radiofrequency ablation system for lung tumours: One year follow‐up from the first multi‐centre large‐scale clinical trial ( BRONC ‐ RFII )
Respirology · 2025-01 · 30 (1) · 51-61
DOI: 10.1111/resp.14822 ↗At a glance
Multizentrische Studie in Respirology, published online on 2024-08-28. Written by Changhao Zhong and 21 co-authors. Institution: State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, National Clinical Research Center for Res…. Major MEDLINE topics: Lung Neoplasms, Radiofrequency Ablation. Cited 21 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: Guangdong special support plan project, Guangzhou Science and Technology Plan Project.
Abstract (original language)
Background and Objective Radiofrequency ablation (RFA) is an emerging treatment of lung cancer, yet it is accompanied by certain safety concerns and operational limitations. This first multi‐centre, large‐scale clinical trial aimed to investigate the technical performance, efficacy and safety of an innovative transbronchial RFA system for lung tumours.
Methods
The study enrolled patients with malignant lung tumours who underwent transbronchial RFA using an automatic saline microperfusion system between January 2021 and December 2021 across 16 medical centres. The primary endpoint was the complete ablation rate. The performance and safety of the technique, along with the 1‐year survival rates, were evaluated.
Results
This study included 126 patients (age range: 23–85 years) with 130 lung tumours (mean size: 18.77 × 14.15 mm) who had undergone 153 transbronchial RFA sessions, with a technique success rate of 99.35% and an average ablation zone size of 32.47 mm. At the 12‐month follow‐up, the complete ablation rate and intrapulmonary progression‐free survival rates were 90.48% and 88.89%, respectively. The results of patients with ground‐glass nodules (GGNs) were superior to those of the patients with solid nodules (12‐month complete ablation rates: solid vs. pure GGN vs. mixed GGN: 82.14% vs. 100% vs. 96.08%, p = 0.007). No device defects were reported. Complications such as pneumothorax, haemoptysis, pleural effusion, pulmonary infection and pleural pain were observed in 3.97%, 6.35%, 8.73%, 11.11% and 10.32% of patients, respectively. Two subjects died during the follow‐up period.
Conclusion
Transbronchial RFA utilizing an automatic saline microperfusion system is a viable, safe and efficacious approach for the treatment for lung tumours, particularly for patients with GGNs. image
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, National Clinical Research Center for Respiratory, Guangzhou Institute of Respiratory Disease, Guangzhou, Guang…
- Department of Respiratory and Critical Care Medicine, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Zhejiang, Hangzhou, People's Republic of China.
- Department of Respiratory and Critical Care Medicine, Affiliated Beijing Chaoyang Hospital of Capital Medical University, Beijing, People's Republic of China.
- Department of Respiratory and Critical Care Medicine, Shandong Provincial Chest Hospital, Jinan, Shandong, People's Republic of China.
- Department of Respiratory and Critical Care Medicine, The Second Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, People's Republic of China.
- Department of Respiratory and Critical Care Medicine, Henan Province People Hospital, Zhengzhou, Henan, People's Republic of China.
ORCID profiles: Zhuquan Su, Difei Chen, Feng Wang, Hongwu Wang, Qing Geng, Felix J F Herth
Funding
- Guangdong special support plan project
- Guangzhou Science and Technology Plan Project
Cite
APA
Zhong, C., Chen, E., Su, Z., Chen, D., Wang, F., Wang, X., Liu, G., Zhang, X., Luo, F., Zhang, N., Wang, H., Jin, L., Long, F., Liu, C., Wu, S., Geng, Q., Wang, X., Tang, C., Chen, R., …, & Li, S. (2025). Safety and efficacy of a novel transbronchial radiofrequency ablation system for lung tumours: One year follow‐up from the first multi‐centre large‐scale clinical trial ( BRONC ‐ RFII ). Respirology, 30(1), 51-61. https://doi.org/10.1111/resp.14822
Vancouver
Zhong C, Chen E, Su Z, Chen D, Wang F, Wang X, et al. Safety and efficacy of a novel transbronchial radiofrequency ablation system for lung tumours: One year follow‐up from the first multi‐centre large‐scale clinical trial ( BRONC ‐ RFII ). Respirology. 2025;30(1):51-61. doi:10.1111/resp.14822
BibTeX
@article{Zhong2025,
author = {Zhong, Changhao and Chen, Enguo and Su, Zhuquan and Chen, Difei and Wang, Feng and Wang, Xiaoping and Liu, Guangnan and Zhang, Xiaoju and Luo, Fengming and Zhang, Nan and Wang, Hongwu and Jin, Longyu and Long, Fa and Liu, Chunfang and Wu, Shiman and Geng, Qing and Wang, Xiang and Tang, Chunli and Chen, Ruchong and Herth, Felix J F and Sun, Jiayuan and Li, Shiyue},
title = {Safety and efficacy of a novel transbronchial radiofrequency ablation system for lung tumours: One year follow‐up from the first multi‐centre large‐scale clinical trial ( BRONC ‐ RFII )},
journal = {Respirology},
year = {2025},
volume = {30},
number = {1},
pages = {51--61},
doi = {10.1111/resp.14822}
}
EUVIMED