EUVIMEDSkopri EUVIMED
Open access

Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy

Or Kalchiem-Dekel iD, Reza Bergemann, Xiaoyue Ma, Paul J Christos, Daniel Miodownik, Yiming Gao, Usman Mahmood, Prasad S Adusumilli, Matthew J Bott, Joseph Dycoco, Daphna Y Gelblum, Robert P Lee and 6 more

Respirology · 2024

DOI: 10.1111/resp.14765 ↗

At a glance

Journal article in Respirology, 2024. Written by Or Kalchiem-Dekel and 17 co-authors. Institution: Section of Interventional Pulmonology, Pulmonary Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York, USA. Major MEDLINE topics: Cone-Beam Computed Tomography, Bronchoscopy, Radiation Exposure, Robotic Surgical Procedures. Cited 19 times so far (Crossref); 48 references. The full text is freely available in PubMed Central. Funded by: NCI NIH HHS, National Institutes of Health/National Cancer Institute.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background and Objective Robotic‐assisted bronchoscopy (RAB) is an emerging modality to sample pulmonary lesions. Cone‐beam computed tomography (CBCT) can be incorporated into RAB. We investigated the magnitude and predictors of patient and staff radiation exposure during mobile CBCT‐guided shape‐sensing RAB.

Methods

Patient radiation dose was estimated by cumulative dose area product (cDAP) and cumulative reference air kerma (cRAK). Staff equivalent dose was calculated based on isokerma maps and a phantom simulation. Patient, lesion and procedure‐related factors associated with higher radiation doses were identified by logistic regression models.

Results

A total of 198 RAB cases were included in the analysis. The median patient cDAP and cRAK were 10.86 Gy cm 2 (IQR: 4.62–20.84) and 76.20 mGy (IQR: 38.96–148.38), respectively. Among staff members, the bronchoscopist was exposed to the highest median equivalent dose of 1.48 μSv (IQR: 0.85–2.69). Both patient and staff radiation doses increased with the number of CBCT spins and targeted lesions ( p < 0.001 for all comparisons). Patient obesity, negative bronchus sign, lesion size

Subjects

MeSH terms (MEDLINE)

Cone-Beam Computed TomographyBronchoscopyRadiation ExposureRobotic Surgical ProceduresHumansMaleFemaleMiddle AgedOccupational ExposureAgedRadiation DosagePhantoms, ImagingAdultLung Neoplasms

Author keywords

bronchoscopycone‐beam computed tomographypulmonary noduleradiation exposure

Authors and institutions

  • Section of Interventional Pulmonology, Pulmonary Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Division of Biostatistics and Epidemiology, Weill Cornell School of Medicine, New York, New York, USA.
  • Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Thoracic Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
  • Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.

ORCID profiles: Or Kalchiem-Dekel, Bryan C Husta

Funding

  • NCI NIH HHS
  • National Institutes of Health/National Cancer Institute

Cite

APA

Kalchiem-Dekel, O., Bergemann, R., Ma, X., Christos, P. J., Miodownik, D., Gao, Y., Mahmood, U., Adusumilli, P. S., Bott, M. J., Dycoco, J., Gelblum, D. Y., Lee, R. P., Park, B. J., Rocco, G., Solomon, S. B., Jones, D. R., Chawla, M., & Husta, B. C. (2024). Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy. Respirology. https://doi.org/10.1111/resp.14765

Vancouver

Kalchiem-Dekel O, Bergemann R, Ma X, Christos PJ, Miodownik D, Gao Y, et al. Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy. Respirology. 2024. doi:10.1111/resp.14765

BibTeX
@article{KalchiemDekel2024,
  author = {Kalchiem-Dekel, Or and Bergemann, Reza and Ma, Xiaoyue and Christos, Paul J and Miodownik, Daniel and Gao, Yiming and Mahmood, Usman and Adusumilli, Prasad S and Bott, Matthew J and Dycoco, Joseph and Gelblum, Daphna Y and Lee, Robert P and Park, Bernard J and Rocco, Gaetano and Solomon, Stephen B and Jones, David R and Chawla, Mohit and Husta, Bryan C},
  title = {Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy},
  journal = {Respirology},
  year = {2024},
  doi = {10.1111/resp.14765}
}
Start for free →