Chest x‐ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers

Ryan F Hoy iD, Catherine Jones, Katrina Newbigin, Michael J Abramson iD, Hayley Barnes iD, Christina Dimitriadis, Samantha Ellis, Deborah C Glass iD, Stella M Gwini iD, Fiona Hore-Lacy iD, Javier Jimenez-Martin, Sundeep S Pasricha and 4 more

Respirology · 2024-09 · 29 (9) · 785-794

DOI: 10.1111/resp.14755 ↗

At a glance

Journal article in Respirology, published online on 2024-05-27. Written by Ryan F Hoy and 15 co-authors. Institution: Monash Centre for Occupational and Environmental Health, School of Public Health & Preventive Medicine, Faculty of Medicine, Nursing and Health Scien…. Major MEDLINE topics: Silicosis, Tomography, X-Ray Computed, Radiography, Thoracic, Occupational Exposure. Cited 16 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: WorkSafe Victoria, Australian Government Medical Research Future Fund.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and Objective Chest x‐ray (CXR) remains a core component of health monitoring guidelines for workers at risk of exposure to crystalline silica. There has however been a lack of evidence regarding the sensitivity of CXR to detect silicosis in artificial stone benchtop industry workers.

Methods

Paired CXR and high‐resolution computed tomography (HRCT) images were acquired from 110 artificial stone benchtop industry workers. Blinded to the clinical diagnosis, each CXR and HRCT was independently read by two thoracic radiologists from a panel of seven, in accordance with International Labour Office (ILO) methodology for CXR and International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Accuracy of screening positive (ILO major category 1, 2 or 3) and negative (ILO major category 0) CXRs were compared with identification of radiological features of silicosis on HRCT.

Results

CXR was positive for silicosis in 27/110 (24.5%) workers and HRCT in 40/110 (36.4%). Of the 83 with a negative CXR (ILO category 0), 15 (18.1%) had silicosis on HRCT. All 11 workers with ILO category 2 or 3 CXRs had silicosis on HRCT. In 99 workers ILO category 0 or 1 CXRs, the sensitivity of screening positive CXR compared to silicosis identified by HRCT was 48% (95%CI 29–68) and specificity 97% (90–100).

Conclusion

Compared to HRCT, sensitivity of CXR was low but specificity was high. Reliance on CXR for health monitoring would provide false reassurance for many workers, delay management and underestimate the prevalence of silicosis in the artificial stone benchtop industry.

Subjects

MeSH terms (MEDLINE)

SilicosisTomography, X-Ray ComputedRadiography, ThoracicOccupational ExposureSensitivity and SpecificityHumansMaleAdultMiddle AgedFemaleOccupational Diseases

Author keywords

artificial stone silicosischest x‐rayhigh resolution computed tomographyscreening

Authors and institutions

  • Monash Centre for Occupational and Environmental Health, School of Public Health & Preventive Medicine, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia.
  • Department of Respiratory Medicine, Alfred Hospital, Melbourne, Victoria, Australia.
  • I-MED Radiology Network, Victoria, Australia.
  • School of Public Health & Preventive Medicine, Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Victoria, Australia.
  • School of Translational Medicine, Monash University, Melbourne, Victoria, Australia.
  • Department of Radiology, Alfred Hospital, Melbourne, Victoria, Australia.

ORCID profiles: Ryan F Hoy, Michael J Abramson, Hayley Barnes, Deborah C Glass, Stella M Gwini, Fiona Hore-Lacy, Miranda Siemienowicz

Funding

  • WorkSafe Victoria
  • Australian Government Medical Research Future Fund

Cite

APA

Hoy, R. F., Jones, C., Newbigin, K., Abramson, M. J., Barnes, H., Dimitriadis, C., Ellis, S., Glass, D. C., Gwini, S. M., Hore-Lacy, F., Jimenez-Martin, J., Pasricha, S. S., Pirakalathanan, J., Siemienowicz, M., Walker-Bone, K., & Sim, M. R. (2024). Chest x‐ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers. Respirology, 29(9), 785-794. https://doi.org/10.1111/resp.14755

Vancouver

Hoy RF, Jones C, Newbigin K, Abramson MJ, Barnes H, Dimitriadis C, et al. Chest x‐ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers. Respirology. 2024;29(9):785-794. doi:10.1111/resp.14755

BibTeX
@article{Hoy2024,
  author = {Hoy, Ryan F and Jones, Catherine and Newbigin, Katrina and Abramson, Michael J and Barnes, Hayley and Dimitriadis, Christina and Ellis, Samantha and Glass, Deborah C and Gwini, Stella M and Hore-Lacy, Fiona and Jimenez-Martin, Javier and Pasricha, Sundeep S and Pirakalathanan, Janu and Siemienowicz, Miranda and Walker-Bone, Karen and Sim, Malcolm R},
  title = {Chest x‐ray has low sensitivity to detect silicosis in artificial stone benchtop industry workers},
  journal = {Respirology},
  year = {2024},
  volume = {29},
  number = {9},
  pages = {785--794},
  doi = {10.1111/resp.14755}
}
Start for free →