Glass wool column filtration for stallion sperm selection: A comparative analysis with the single‐layer colloid centrifugation
Reproduction in Domestic Animals · 2023
DOI: 10.1111/rda.14424 ↗At a glance
Journal article in Reproduction in Domestic Animals, 2023. Written by Giuliana Elizabeth Zevallos Valenzuela and 5 co-authors. Institution: Instituto de Biología y Medicina Experimental (IBYME), Consejo Nacional de Investigaciones Científicas y Técnicas de Argentina (CONICET), Fundación I…. Major MEDLINE topics: Semen Preservation, Bison. Cited 2 times so far (Crossref); 21 references. Funded by: CONICET PIP881, Fundación René Barón, Fundación Williams.
Abstract (original language)
Glass wool column filtration (GWCF) selects human, bull, boar, dog and buffalo spermatozoa, but reports in the horse are scarce. Single‐layer colloid centrifugation with Androcoll‐E™ is currently the standard procedure to select good‐quality equine sperm. This study was designed to assess GWCF (50 and 75 mg columns; GWCF‐50 and GWCF‐75, respectively) efficacy to select good‐quality sperm from fresh and frozen–thawed equine semen, and to compare its performance with Androcoll‐E™ colloid centrifugation. Percentage total motile (TM), progressively motile (PM), morphologically normal (MN), osmotically competent (HOS+) and acrosome‐intact/osmotically competent (AI/HOS+) sperm were determined. In studies done with fresh semen samples ( n = 17), suspensions subjected to GWCF‐50 showed an improvement ( p < .05) in PM and HOS+ sperm after selection. With GWCF‐75, an increase ( p < .05) in PM, MN and HOS+ sperm was observed. Results with GWCF were comparable or better than with Androcoll‐E™ selection. Sperm recovery was similar between procedures for all semen parameters. Total sperm count recovery was lower after GWCF‐75 (GWCF‐50 = 60.0; GWCF‐75 = 51.0; Androcoll‐E™ = 76.0 million sperm; median; p = .013), but results on total progressive sperm count were similar (GWCF‐50 = 23.0; GWCF‐75 = 27.0; Androcoll‐E™ = 24.0 million sperm; median; p = .3850). Using frozen–thawed semen samples ( n = 16), an improvement ( p < .05) in TM, PM, NM, HOS+ and AI/HOS+ sperm was observed in GWCF‐75 filtrates. Results were comparable to Androcoll‐E™ centrifugation, except HOS+ that increased ( p < .05) only after GWCF‐75. Recovery was comparable for all parameters in frozen samples. GWCF is a simple and low‐cost procedure that selects equine sperm with a quality comparable to colloid centrifugation with Androcoll‐E™.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Instituto de Biología y Medicina Experimental (IBYME), Consejo Nacional de Investigaciones Científicas y Técnicas de Argentina (CONICET), Fundación IBYME (FIBYME), Buenos Aires, Argentina.
- Cátedra de Teriogenología, UBA, Facultad de Ciencias Veterinarias, Instituto de Investigación y Tecnología en Reproducción Animal, Buenos Aires, Argentina.
ORCID profiles: Mónica Hebe Vazquez-Levin
Funding
- CONICET PIP881
- Fundación René Barón
- Fundación Williams
Cite
APA
Zevallos Valenzuela, G. E., Ferrante, A., Verón, G. L., Miragaya, M., Marín-Briggiler, C. I., & Vazquez-Levin, M. H. (2023). Glass wool column filtration for stallion sperm selection: A comparative analysis with the single‐layer colloid centrifugation. Reproduction in Domestic Animals. https://doi.org/10.1111/rda.14424
Vancouver
Zevallos Valenzuela GE, Ferrante A, Verón GL, Miragaya M, Marín-Briggiler CI, Vazquez-Levin MH. Glass wool column filtration for stallion sperm selection: A comparative analysis with the single‐layer colloid centrifugation. Reproduction in Domestic Animals. 2023. doi:10.1111/rda.14424
BibTeX
@article{ZevallosValenzuela2023,
author = {Zevallos Valenzuela, Giuliana Elizabeth and Ferrante, Alejandro and Verón, Gustavo Luis and Miragaya, Marcelo and Marín-Briggiler, Clara Isabel and Vazquez-Levin, Mónica Hebe},
title = {Glass wool column filtration for stallion sperm selection: A comparative analysis with the single‐layer colloid centrifugation},
journal = {Reproduction in Domestic Animals},
year = {2023},
doi = {10.1111/rda.14424}
}
EUVIMED