EUVIMEDEUVIMED entdecken
Crossref

MEGAP : A Comprehensive Pipeline for Automatic Preprocessing of Large‐Scale Magnetoencephalography Data

Seyyed Erfan Mohammadi iD, Hasti Shabani, Mohammad Mahdi Begmaz, Narjes Soltani Dehaghani iD

Psychophysiology · 2025-07 · 62 (7)

DOI: 10.1111/psyp.70109 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Psychophysiology, online erschienen am 07.07.2025. Verfasst von Seyyed Erfan Mohammadi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Science and Technology, Shahid Beheshti University, Tehran, Iran. Hauptthemen laut MEDLINE: Magnetoencephalography, Artifacts, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetoencephalography (MEG) data are often contaminated by various noise and artifacts, necessitating meticulous preprocessing. However, no pipeline has comprehensively examined all aspects of the different types of MEG noise, nor has any automatic preprocessing pipeline ever been presented. The impracticality of performing visual inspections for the preprocessing of large‐scale resting state datasets, combined with the absence of automation, hinders the ability to take advantage of such datasets, including increased generalizability. Additionally, the absence of a standardized sequence for MEG preprocessing steps affects the reproducibility of research studies. Our MEG Automatic Pipeline (MEGAP) can automatically reduce noise and artifacts and is the first pipeline that can be used to preprocess large‐scale resting state MEG datasets. We developed this pipeline by integrating and sequencing recent algorithms for each preprocessing step, ensuring automated execution, standardization, and organized outputs. The key features of MEGAP include correcting head movements, removing line noise without applying a notch filter, annotating muscle artifacts, removing sensor and environmental noise, and automatically detecting artifact components in Independent Component Analysis (ICA). We validated our pipeline using simulated and experimental data from the Cambridge Centre for Aging and Neuroscience (Cam‐CAN) dataset. Substantial improvements were achieved based on different evaluation criteria such as Normalized Mean Square Error (NMSE), correlation, and Signal to Noise Ratio (SNR). MEGAP provides a robust framework for MEG data preprocessing, significantly reducing the manual effort in preprocessing by automating the required steps, contributing to more consistent and reproducible neuroimaging research outcomes, and facilitating the analysis of large‐scale MEG studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnetoencephalographyArtifactsSignal Processing, Computer-AssistedHumansAlgorithmsAdultReproducibility of ResultsFemale

Stichwörter der Autor:innen

automaticlarge‐scale datamagnetoencephalographypipelinepreprocessing

Autor:innen und Institutionen

  • Institute of Medical Science and Technology, Shahid Beheshti University, Tehran, Iran.
  • Department of Computer Science, Shahid Beheshti University, Tehran, Iran.

ORCID-Profile: Seyyed Erfan Mohammadi, Narjes Soltani Dehaghani

Zitieren

APA

Mohammadi, S. E., Shabani, H., Begmaz, M. M., & Dehaghani, N. S. (2025). MEGAP : A Comprehensive Pipeline for Automatic Preprocessing of Large‐Scale Magnetoencephalography Data. Psychophysiology, 62(7). https://doi.org/10.1111/psyp.70109

Vancouver

Mohammadi SE, Shabani H, Begmaz MM, Dehaghani NS. MEGAP : A Comprehensive Pipeline for Automatic Preprocessing of Large‐Scale Magnetoencephalography Data. Psychophysiology. 2025;62(7). doi:10.1111/psyp.70109

BibTeX
@article{Mohammadi2025,
  author = {Mohammadi, Seyyed Erfan and Shabani, Hasti and Begmaz, Mohammad Mahdi and Dehaghani, Narjes Soltani},
  title = {MEGAP : A Comprehensive Pipeline for Automatic Preprocessing of Large‐Scale Magnetoencephalography Data},
  journal = {Psychophysiology},
  year = {2025},
  volume = {62},
  number = {7},
  doi = {10.1111/psyp.70109}
}
Kostenlos starten →