EUVIMEDExplore EUVIMED
Crossref

Low‐temperature luminescence and curcumin‐sensitized singlet oxygen generation

Vitaly Yu Plavskii iD, Andrei N Sobchuk, Aliaksandr V Mikulich iD, Olga N Dudinova, Antonina I Tretyakova, Ludmila G Plavskaya, Tatsiana S Ananich, Valentin N Knyukshto

Photochemistry and Photobiology · 2026-06-12

DOI: 10.1111/php.70125 ↗

At a glance

Journal article in Photochemistry and Photobiology, published online on 2026-06-12. Written by Vitaly Yu Plavskii and 7 co-authors. Institution: State Scientific Institution "B.I. Stepanov Institute of Physics of the National Academy of Sciences of Belarus", Minsk, Republic of Belarus. 48 references. Funded by: Belarusian Republican Foundation for Fundamental Research.

AbstractSubjectsBibliographic detailsCiteRelated studies

Abstract (original language)

Detailed comparative studies of spectral and fluorescent properties of curcumin in solutions at room temperature (293 K) and in rigid glass matrices of 2‐methyltetrahydrofuran and ethanol at liquid nitrogen temperature (77 K) were carried out. It was shown that the transition to low temperature, accompanied by a decrease in the efficacy of non‐radiative processes, manifests itself (depending on the solvent) in a 3‐ to 7‐fold increase in the fluorescence quantum yield and fluorescence decay time, a sharp decrease in the Stokes shift, and the appearance of a vibrational structure in the fluorescence and fluorescence excitation spectra of curcumin. Rigid glass matrices were used to record phosphorescence, the attribution of which to curcumin was confirmed for the first time by the correspondence of its excitation spectrum to the fluorescence excitation spectrum at 77 K. The phosphorescence maximum of curcumin was shown to be located at = 635 nm, which differs significantly from the data (= 730 nm) of the most cited work on curcumin photonics. The quantum yield of curcumin phosphorescence and its decay times were estimated for each solvent. By monitoring the luminescence of curcumin‐sensitized singlet oxygen generation in the 1270 nm region, its quantum yield ( φ Δ ) was determined in a number of organic solvents. The obtained values φ Δ are 1.4–2.0 times higher than the literature data from 30 years ago.

Subjects

Author keywords

293 K77 Kcurcuminfluorescence decay timefluorescence quantum yieldglass matriceslow‐temperature luminescencephosphorescencesinglet oxygenstokes shift

Authors and institutions

  • State Scientific Institution "B.I. Stepanov Institute of Physics of the National Academy of Sciences of Belarus", Minsk, Republic of Belarus.

ORCID profiles: Vitaly Yu Plavskii, Aliaksandr V Mikulich

Funding

  • Belarusian Republican Foundation for Fundamental Research

Cite

APA

Plavskii, V. Y., Sobchuk, A. N., Mikulich, A. V., Dudinova, O. N., Tretyakova, A. I., Plavskaya, L. G., Ananich, T. S., & Knyukshto, V. N. (2026). Low‐temperature luminescence and curcumin‐sensitized singlet oxygen generation. Photochemistry and Photobiology. https://doi.org/10.1111/php.70125

Vancouver

Plavskii VY, Sobchuk AN, Mikulich AV, Dudinova ON, Tretyakova AI, Plavskaya LG, et al. Low‐temperature luminescence and curcumin‐sensitized singlet oxygen generation. Photochemistry and Photobiology. 2026. doi:10.1111/php.70125

BibTeX
@article{Plavskii2026,
  author = {Plavskii, Vitaly Yu and Sobchuk, Andrei N and Mikulich, Aliaksandr V and Dudinova, Olga N and Tretyakova, Antonina I and Plavskaya, Ludmila G and Ananich, Tatsiana S and Knyukshto, Valentin N},
  title = {Low‐temperature luminescence and curcumin‐sensitized singlet oxygen generation},
  journal = {Photochemistry and Photobiology},
  year = {2026},
  doi = {10.1111/php.70125}
}
Start for free →