Inactivation of bio-aerosolized viruses by applying pulsed electric field
Environmental Pollution · 2026
DOI: 10.1016/j.envpol.2026.127841 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Pollution, 2026. Verfasst von Takashi Furukawa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Science, School of Allied Health Sciences, Kitasato University, 1-15-1, Kitasato, Sagamihara, 252-0373, Japan. Electronic addres…. Hauptthemen laut MEDLINE: Virus Inactivation, Electricity. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, JST Adaptable and Seamless Technology Transfer Program Through Target-driven R and D, Kitasato University School of Allied Health Sciences.
Abstract (Originalsprache)
Coronavirus disease 19 (COVID-19) pandemic has highlighted the need for effective countermeasures to prevent the transmission of infectious viruses contained in bio-aerosols, particularly in indoor environments with limited ventilation. Pulsed electric fields (PEF) can electrically capture aerosols and inactivate microorganisms within these aerosols. Our study, with the goal of establishing a new spatial purification technology utilizing PEF, aimed to clarify the inactivation effect of PEF on bio-aerosolized viruses. Bacteriophages phi6 and MS2 were used as viral surrogates representing enveloped and non-enveloped viruses, respectively. Preliminary studies were conducted to optimize the experimental conditions of the bench-scale aerosolized virus inactivation experimental chamber constructed to evaluate the performance of aerosolized virus removal. Based on the recovery efficiency of phi6 and the time efficiency, condition A (aerosolized amount: 1 mL, vacuum pump flow rate: 20 L/min, and recovery time: 1 min) was determined to be the preferable condition for inactivation experiments. Under the PEF application condition at 10 kV for 15 min, the maximum log reduction values (LRVs) for phi6 and MS2 were 3.62 ± 0.33 and 3.56 ± 0.08, respectively. Therefore, PEF showed a high reduction of both enveloped and non-enveloped viruses in bio-aerosol, indicating that PEF can effectively inactivate viruses independent of differences in virus particle structures. Conversely, cDNA concentrations of both bacteriophages did not change under all PEF application conditions (p > 0.05), suggesting that PEF possibly inactivated viruses by altering the protein structures of their host recognition sites, thereby causing them to lose their infectious capacity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Health Science, School of Allied Health Sciences, Kitasato University, 1-15-1, Kitasato, Sagamihara, 252-0373, Japan. Electronic address: tfuruka@kitasato-u.ac.jp.
- Department of Electrical and Electronic Engineering, National Institute of Technology, Oita College, 1666 Maki, Oita, 870-0152, Japan.
- Department of Health Science, School of Allied Health Sciences, Kitasato University, 1-15-1, Kitasato, Sagamihara, 252-0373, Japan.
- Department of Medical Laboratory Sciences, School of Allied Health Sciences, Kitasato University, 1-15-1, Kitasato, Sagamihara, 252-0373, Japan; Research Facility of Regenerative Medicine and Cell Design, School of Alli…
- Graduate School of Engineering, Tohoku University, 6-6-06, Aoba-Ku, Sendai, 980-8579, Japan.
Förderung
- Japan Society for the Promotion of Science
- JST Adaptable and Seamless Technology Transfer Program Through Target-driven R and D
- Kitasato University School of Allied Health Sciences
Zitieren
APA
Furukawa, T., Ueno, T., Moroishi, S., Hoshiko, Y., Maehana, S., Amarasiri, M., & Sei, K. (2026). Inactivation of bio-aerosolized viruses by applying pulsed electric field. Environmental Pollution. https://doi.org/10.1016/j.envpol.2026.127841
Vancouver
Furukawa T, Ueno T, Moroishi S, Hoshiko Y, Maehana S, Amarasiri M, et al. Inactivation of bio-aerosolized viruses by applying pulsed electric field. Environmental Pollution. 2026. doi:10.1016/j.envpol.2026.127841
BibTeX
@article{Furukawa2026,
author = {Furukawa, Takashi and Ueno, Takahisa and Moroishi, Suzuha and Hoshiko, Yuki and Maehana, Shotaro and Amarasiri, Mohan and Sei, Kazunari},
title = {Inactivation of bio-aerosolized viruses by applying pulsed electric field},
journal = {Environmental Pollution},
year = {2026},
doi = {10.1016/j.envpol.2026.127841}
}
EUVIMED