Spectral Mismatch Effect of Ultraviolet Radiometers in Actual UV‐C Measurement

Yuki Iwasa iD, Kenichi Kinoshita iD, Hiroshi Shitomi iD

Photochemistry and Photobiology · 2023-09 · 99 (5) · 1240-1247

DOI: 10.1111/php.13765 ↗

At a glance

Journal article in Photochemistry and Photobiology, published online on 2023-01-04. Written by Yuki Iwasa and 2 co-authors. Institution: National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, Japan. Cited 3 times so far (Crossref); 22 references.

SažetakBibliografski podaciCiteRelated studies

Abstract (original language)

The management of radiant exposure to ultraviolet (UV) radiation, especially in the wavelength range from 100 nm to 280 nm ( i.e. UV‐C), is important for virus inactivation or photobiological safety. Recently, many commercial UV radiometers have been used to measure UV‐C irradiance for industrial and public applications. The accuracy of the four types of commercial UV radiometers was investigated by comparing the reference irradiance values obtained from the spectral irradiance standard. It was found that the displayed values of the UV radiometers have discrepancies, such that the measured value can be more than twice the actual value in a certain case. The spectral mismatch between the calibration and test sources is a major factor in the discrepancies in the UV‐C measurements. With spectral mismatch correction, most corrected values show a tendency to improve the result to approaching the reference values within 20%. Users need to provide spectral information about the source and radiometer used for UV‐C measurement.

Authors and institutions

  • National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Ibaraki, Japan.

ORCID profiles: Yuki Iwasa, Kenichi Kinoshita, Hiroshi Shitomi

Cite

APA

Iwasa, Y., Kinoshita, K., & Shitomi, H. (2023). Spectral Mismatch Effect of Ultraviolet Radiometers in Actual UV‐C Measurement. Photochemistry and Photobiology, 99(5), 1240-1247. https://doi.org/10.1111/php.13765

Vancouver

Iwasa Y, Kinoshita K, Shitomi H. Spectral Mismatch Effect of Ultraviolet Radiometers in Actual UV‐C Measurement. Photochemistry and Photobiology. 2023;99(5):1240-1247. doi:10.1111/php.13765

BibTeX
@article{Iwasa2023,
  author = {Iwasa, Yuki and Kinoshita, Kenichi and Shitomi, Hiroshi},
  title = {Spectral Mismatch Effect of Ultraviolet Radiometers in Actual UV‐C Measurement},
  journal = {Photochemistry and Photobiology},
  year = {2023},
  volume = {99},
  number = {5},
  pages = {1240--1247},
  doi = {10.1111/php.13765}
}
Start for free →