Effect of real-time carbon dioxide sensing stylet-assisted endotracheal intubation: A case-crossover manikin simulation study
The American Journal of Emergency Medicine · 2025
DOI: 10.1016/j.ajem.2025.05.047 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift The American Journal of Emergency Medicine, 2025. Verfasst von Yoonjic Kim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Seoul National University Hospital Department of Emergency Medicine, Jongno-gu, Seoul 03080, South Korea. Hauptthemen laut MEDLINE: Capnography, Carbon Dioxide, Intubation, Intratracheal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Seoul National University Hospital.
Abstract (Originalsprache)
BACKGROUND: Endotracheal intubation is an important emergency procedure, especially in critical care settings. Capnography-guided intubation (CGI) is a technology that may enhance procedural efficiency. This study aimed to compare the effectiveness of CGI with conventional intubation (CI) using a manikin simulation. METHODS: A case-crossover manikin simulation study was conducted with three clinical scenarios: normal airway, cervical immobilization, and cardiopulmonary resuscitation. A CO2-exhalation simulation manikin was developed for this purpose. Participants were randomly assigned to perform CGI or CI first, followed by the alternative method. The primary outcome was the first-attempt success rate, and the secondary outcome was the procedure time of intubation. A linear mixed-effects model with a random effect for each subject was applied. RESULTS: A total of 40 participants were enrolled, and 20 in each study group. The first-attempt success rate was higher with CGI than CI across all clinical situations, with statistically significant differences in the normal airway and cervical immobilization settings. Specifically, for the normal airway, the success rate was 40 (100.0 %) for CGI vs. 33 (82.5 %) for CI [abs diff: 17.5 %, 95 % CI: 5.7 %-29.3 %]; for cervical immobilization, 39 (97.5 %) vs. 32 (80.0 %) [abs diff: 17.5 %, 95 % CI: 4.2 %-30.8 %]; and for cardiopulmonary resuscitation, 40 (100.0 %) vs. 38 (95.0 %) [abs diff: 5.0 %, 95 % CI: -1.8 %-11.8 %]. The intubation time was shorter with CGI in the normal airway and cervical immobilization scenarios. The median [interquartile range (IQR)] time for normal airway was 23.5 (19.2-28.4) sec for CGI vs. 31.6 (22.2-59.7) sec for CI, and for cervical immobilization, 24.4 (20.4-30.8) sec for CGI vs. 28.6 (22.6-56.9) sec for CI. In cardiopulmonary resuscitation, the median [IQR] was 23.1 (19.6-31.4) sec for CGI vs. 25.1 (18.6-32.4) sec for CI. CONCLUSION: In the manikin-based randomized crossover simulation, CGI achieved a higher first-attempt success rate and shorter intubation time than CI in the normal airway and cervical immobilization scenarios.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Seoul National University Hospital Department of Emergency Medicine, Jongno-gu, Seoul 03080, South Korea.
- Seoul National University Hospital Department of Emergency Medicine, Jongno-gu, Seoul 03080, South Korea. Electronic address: emphysiciankkh@gmail.com.
- Department of Biomedical Engineering, Seoul National University College of Medicine, Jongno-gu, Seoul 03080, South Korea.
- Laboratory of Emergency Medical Services, Seoul National University Hospital Biomedical Research Institute, Jongno-gu, Seoul 03080, South Korea.
- Seoul Metropolitan BORAMAE Medical Center Department of Emergency Medicine, Dongjak-gu, Seoul 07061, South Korea.
Förderung
- Seoul National University Hospital
Zitieren
APA
Kim, Y., Joo, Y. H., Kim, K. H., Choi, D. H., Kang, H. J., Hong, K. J., Song, K. J., & Shin, S. D. (2025). Effect of real-time carbon dioxide sensing stylet-assisted endotracheal intubation: A case-crossover manikin simulation study. The American Journal of Emergency Medicine. https://doi.org/10.1016/j.ajem.2025.05.047
Vancouver
Kim Y, Joo YH, Kim KH, Choi DH, Kang HJ, Hong KJ, et al. Effect of real-time carbon dioxide sensing stylet-assisted endotracheal intubation: A case-crossover manikin simulation study. The American Journal of Emergency Medicine. 2025. doi:10.1016/j.ajem.2025.05.047
BibTeX
@article{Kim2025,
author = {Kim, Yoonjic and Joo, Yoon Ha and Kim, Ki Hong and Choi, Dong Hyun and Kang, Hyun Jeong and Hong, Ki Jeong and Song, Kyoung Jun and Shin, Sang Do},
title = {Effect of real-time carbon dioxide sensing stylet-assisted endotracheal intubation: A case-crossover manikin simulation study},
journal = {The American Journal of Emergency Medicine},
year = {2025},
doi = {10.1016/j.ajem.2025.05.047}
}
EUVIMED