INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double‐blind, single‐center study
Pediatric Anesthesia · 2024
DOI: 10.1111/pan.14940 ↗At a glance
Randomisierte kontrollierte Studie in Pediatric Anesthesia, 2024. Written by Wataru Sakai and 6 co-authors. Institution: Department of Anesthesiology, Sapporo Medical University School of Medicine, Sapporo, Hokkaido, Japan. Major MEDLINE topics: Intensive Care Units, Pediatric, Catheterization, Peripheral, Anesthesia, Local, Anesthetics, Local. Cited 1 times so far (Crossref); 25 references.
Topics: Intensivpflege
Abstract (original language)
Background
Quick arterial cannulation is required in pediatric emergency situation, which require effective local anesthesia to avoid withdrawal movement. However, pediatric local anesthesia could be difficult because of withdrawal movement. Jet injectors, which are needleless and provide local anesthesia quickly, could be helpful for pediatric local anesthesia during arterial cannulation.
Aims
This study aimed to examine whether new jet injector “INJEX50” could improve the success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with the current standard of care, infiltration using a 26‐gauge needle.
Methods
This study was a randomized, double‐blind, single‐center study. Participants were infants and young children in the pediatric intensive care unit, who required an arterial line. Local anesthesia was performed with either a 26‐gauge needle (group C) or INJEX50 (group I) before arterial cannulation. The primary outcome (success of local anesthesia) was the presence of withdrawal movement at the time of skin puncture for arterial cannulation. The secondary outcomes included rescue sedation during arterial cannulation. Data were analyzed using Fisher's exact test and the Mann–Whitney U ‐test, with values of p < .05 considered statistically significant.
Results
Seventy patients were randomly assigned to groups C and I. The local anesthesia success rate in group I (30/35 [86%]) was significantly higher than that in group C (15/35 [43%], odds ratio, 8.00; 95% confidence interval, 2.51–25.5; p = .0005). In conclusion, INJEX50 could improve success rate of local anesthesia for arterial cannulation in pediatric intensive care unit compared with 26‐gauge needle.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Anesthesiology, Sapporo Medical University School of Medicine, Sapporo, Hokkaido, Japan.
- Intensive Care Unit, Hokkaido Medical Center for Child Health and Rehabilitation, Sapporo, Hokkaido, Japan.
ORCID profiles: Wataru Sakai, Tomohiro Chaki
Cite
APA
Sakai, W., Chaki, T., Tachibana, S., Ichisaka, Y., Nawa, Y., Nawa, T., & Yamakage, M. (2024). INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double‐blind, single‐center study. Pediatric Anesthesia. https://doi.org/10.1111/pan.14940
Vancouver
Sakai W, Chaki T, Tachibana S, Ichisaka Y, Nawa Y, Nawa T, et al. INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double‐blind, single‐center study. Pediatric Anesthesia. 2024. doi:10.1111/pan.14940
BibTeX
@article{Sakai2024,
author = {Sakai, Wataru and Chaki, Tomohiro and Tachibana, Shunsuke and Ichisaka, Yuki and Nawa, Yuko and Nawa, Tomohiro and Yamakage, Michiaki},
title = {INJEX50 could improve the success rate of local anesthesia for arterial cannulation in the pediatric intensive care unit: A randomized, double‐blind, single‐center study},
journal = {Pediatric Anesthesia},
year = {2024},
doi = {10.1111/pan.14940}
}
EUVIMED