EUVIMEDEUVIMED entdecken
Crossref

Outcomes of Transvenous Lead Extraction for Infectious Versus Non‐Infectious Indications

Adivitch Sripusanapan iD, Natee Deepan iD, Nattawat Charoenpoonsiri, Narut Prasitlumkum iD, Pattara Rattanawong iD, Krit Jongnarangsin, Jakrin Kewcharoen iD

Pacing and Clinical Electrophysiology · 11.11.2026

DOI: 10.1111/pace.70496 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 11.11.2026. Verfasst von Adivitch Sripusanapan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA. Die Arbeit nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transvenous lead extraction (TLE) is performed for both infectious and non‐infectious cardiac implantable electronic device (CIED) indications. Infectious indications are associated with greater systemic illness, whereas non‐infectious leads are generally older and more fibrotic. Whether these competing factors differentially influence TLE outcomes remains unclear.

Methods

We searched PubMed, Embase, Scopus, and CENTRAL through October 10, 2026 for studies directly comparing TLE outcomes between infectious and non‐infectious indications. Trial registries, conference abstracts, and preprint servers were screened. The primary outcome was all‐cause mortality. Secondary outcomes included procedural success and complications. Random‐effects models were used.

Results

Fifteen observational studies comprising 53,086 patients were included. Infectious indications were associated with higher all‐cause mortality (OR 5.61, 95% CI 3.78–8.33; I 2 = 82.3%). The association was greater for short‐term than long‐term mortality (OR 8.57 vs. 2.67; p for interaction < 0.001). Intermediate‐term mortality was also higher (OR 3.84, 95% CI 2.50–5.91). Pericardial complications were less frequent with infectious indications (OR 0.71, 95% CI 0.53–0.95). Clinical and complete procedural success and other complications did not differ significantly.

Conclusion

Infectious indications were associated with higher mortality, particularly in the short term, whereas procedural success was comparable. Variation in follow‐up and infection phenotype likely contributed to heterogeneity.

Schlagwörter

Stichwörter der Autor:innen

CIED infectioncardiac implantable electronic devicemeta‐analysisprocedural outcomestransvenous lead extraction

Autor:innen und Institutionen

  • Department of Medicine, John A. Burns School of Medicine, University of Hawaii, Honolulu, Hawaii, USA.
  • Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, Arizona, USA.
  • Division of Cardiovascular Medicine, Department of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Center of Excellence in Arrhythmia Research, Cardiac Center, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Department of Cardiovascular Medicine, Pali Momi Medical Center, Hawaii, Pacific Health, Aiea, Hawaii, USA.
  • Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Adivitch Sripusanapan, Natee Deepan, Narut Prasitlumkum, Pattara Rattanawong, Jakrin Kewcharoen

Zitieren

APA

Sripusanapan, A., Deepan, N., Charoenpoonsiri, N., Prasitlumkum, N., Rattanawong, P., Jongnarangsin, K., & Kewcharoen, J. (2026). Outcomes of Transvenous Lead Extraction for Infectious Versus Non‐Infectious Indications. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70496

Vancouver

Sripusanapan A, Deepan N, Charoenpoonsiri N, Prasitlumkum N, Rattanawong P, Jongnarangsin K, et al. Outcomes of Transvenous Lead Extraction for Infectious Versus Non‐Infectious Indications. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70496

BibTeX
@article{Sripusanapan2026,
  author = {Sripusanapan, Adivitch and Deepan, Natee and Charoenpoonsiri, Nattawat and Prasitlumkum, Narut and Rattanawong, Pattara and Jongnarangsin, Krit and Kewcharoen, Jakrin},
  title = {Outcomes of Transvenous Lead Extraction for Infectious Versus Non‐Infectious Indications},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70496}
}
Kostenlos starten →